Bosch AMAX 2100 Installation Manual page 61

Hide thumbs Also See for AMAX 2100:
Table of Contents

Advertisement

AMAX 2100 / 3000 / 4000
Unverified alarm
report / cross zone
Domestic no.
Zone Bypass
If this option is enabled, the operator can bypass zones before arming the system. If this
option is disabled, manual bypass of the zone is not available. After manual bypass of the
zone, a zone bypass report is sent.
The zone bypass is valid in only one arming period and will be resumed after disarming. Before
disarming, the bypassed zones ignore all zone triggering and restoration events.
The key switch zone cannot be bypassed.
Forced Arming
If this option is selected, the system can be armed when the zone is in triggering status. If this
option is not selected, the system does not allow the user to arm the system unless the zone
with problems has resumed to normal status or been manually bypassed.
The arming with a zone in triggering status is called forced arming.
When the operating system arms:
Bosch Sicherheitsysteme GmbH
1
2
3
4
5
6
7
0
1
2
3
0
1
2
3
4
5
6
7
When the keypad or key switch zone is used to execute system arming, the system will
show the zone status at first. If a zone in triggering status is not bypassed and the forced
arming option is in disabled status, it cannot be successfully armed.
Receiver 1
Receiver 2
Receiver 3
Receiver 4
Receiver 1, 2, 3, and 4
Receiver 1 (2, 3, and 4 for backup)
Receiver 1 (2 for backup) and receiver 3 (4 for backup)
Disabled
Unverified alarm report
Cross zone
All
Follow 'alarm report' option's logic. range 0-7
No reports allowed
Report to destination 1
Report to destination 2
Report to destination 3
Report to destination 4
Report to destination 1 ,2, 3, 4
Report to destination 1 (where 2, 3, and 4 backup)
Report to destination 1 (where 2 Backup) and 3 (where 4
backup)
Installation Guide
Settings | en