Bosch AMAX 2100 Installation Manual page 149

Hide thumbs Also See for AMAX 2100:
Table of Contents

Advertisement

AMAX 2100 / 3000 / 4000
Date and time is not set after the system is powered on.
Restore:
4
Supervise:
1.
2.
3.
6 - Communication Failure
Condition:
The panel can not send the report to the destination 1 after four attempts.
Restore:
Make sure that reports can be sent and reset the fault. For more information refer to System
Setting, page 66.
Supervise:
1.
2.
P
7- Tamper
Condition:
Onboard panel tamper input is open.
Restore:
4
Supervise:
1.
2.
P
Condition:
Keypad 1 is open and the tamper contact is triggered.
Restore:
4
Supervise:
1.
Bosch Sicherheitsysteme GmbH
Program date and time and reset the fault. For more information refer to System Setting,
page 66.
Report the date and time fault to the configured destination programmed on location
124.
Slow flash FAULT indicator (refer to Keypad Indicators, page 10 for a detailed description)
No report to the AMAX panel system, when date and time setting is recorded in
nonvolatile memory and AMAX Panel is reset. The FAULT indicator is turned off when
there is no other system fault.
Communication Fault 1 - 4
Report the fault to configured destination on address 124 when the fault is detected.
Slow flash FAULT indicator (refer to Keypad Indicators, page 10 for a detailed description).
When the fault is reset, send the restored report to the configured destinations.
The FAULT indicator is turned off when there is no other system fault.
System Tamper
Close the panel tamper input and reset the fault.
Report the tamper condition to configured destination on address 124 when the tamper
condition is detected.
Slow flash FAULT indicator (refer to Keypad Indicators, page 10 for a detailed description).
When the tamper condition is reset, send the restored report to the configured
destinations.
The FAULT indicator is turned off when there is no other system fault.
Keypad 1-16 Tamper
Close the keypad and reset the tamper condition.
Report the tamper condition to configured destination on address 124 when the tamper
condition is detected.
Installation Guide
Troubleshooting | en
149
2014.11 | 02 | F.01U.267.112

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Amax 3000Amax 4000

Table of Contents