AMAX 2100 / 3000 / 4000
3.
02 - Interior Instant
The interior instant zone type performs as described below:
1.
2.
3.
03 – Delay 1
The delay 1 zone type performs as described below:
1.
2.
3.
04 - Interior Delay 1
The interior delay 1 zone type performs as described below:
1.
Bosch Sicherheitsysteme GmbH
–
Zone normal - no alarm / no report
–
Zone triggered - alarm / report
–
(Zone triggered during exit time no alarm / no report)
–
(Zone triggered during entry time alarm / report is delayed for 30 second or entry
time is expired, when system is disarmed before, no report)
STAY Arm:
–
Zone normal - no alarm / no report
–
Zone triggered - alarm / report
–
(Zone triggered during exit time no alarm / no report)
–
(Zone triggered during entry time alarm / report is delayed for 30 second / entry time
is expired, when system is disarmed before, no report) When zone is triggered, not
bypassed and system is forced to arm, a zone fault report is sent.
–
When the system is disarmed and zone is not restored before, a Zone fault restore
report is sent.
Disarm:
–
same as the instant zone disarm status
AWAY Arm:
–
same as the instant zone AWAY arm status
STAY Arm:
–
This zone will be ignored and performed as disarm. Refer to Keypad Indicators to see
how the zone is displayed during exit time.
–
When zone is triggered, not bypassed and system is forced to arm, a zone fault
report is send.
–
When system is disarmed and zone is not restored before, a zone fault restore report
is sent.
Disarm: same as instant zone disarm status
AWAY Arm:
–
Zone normal - no alarm / no report
–
Zone triggered - entry time starts - no alarm / no report
–
Disarming during entry time - no alarm / no report
–
Zone triggered - during exit time - no alarm / no report
–
Zone triggered - during entry time - no alarm / no report
–
Zone triggered - entry time is expired - alarm / report
–
(report is delayed for a specified time (default: 30s; value range: 00-99), when
system is disarmed before, no report)
STAY Arm: same as AWAY arm performance.
–
First delay zone will start the entry time; all other delay zones will follow.
–
When system is disarmed and zone is not restored before, a zone restore report is
sent.
Disarm: same as the instant zone disarm status
Installation Guide
Settings | en
51