Bosch AMAX 2100 Installation Manual page 67

Hide thumbs Also See for AMAX 2100:
Table of Contents

Advertisement

AMAX 2100 / 3000 / 4000
Date/Time Fault
In case of date/time settings fault, it is possible to choose to display the fault or transmit fault
prompt tone at the same time, or to not display and stop fault prompt tone. If it is chosen to
not display, the fault prompt tone is set, and the system will prompt nothing if no date and
time are set after power-up.
Battery Check Interval
This option defines the time interval in which the battery test is carried out (01 – 15 minutes;
00 = disabled). The battery test is also carried out when the system is armed or during system
power up.
Phone Line Monitor
If this option is enabled, the system supervises whether the phone line is broken or
disconnected.
Siren Supervision
If this option is enabled, the system supervises whether the siren is shortened or
disconnected.
AC Fault Auto Reset
This option enables/disables the automatic AC fault reset function.
If this option is enabled, an AC fault indication is restored automatically after the AC power
supply is restored.
If this option is disabled, an AC fault indication has to be reset manually after the AC power
supply is restored.
Communication Fault Auto Reset
This option enables/disables the automatic communication fault reset function.
If this option is enabled, a communication fault indication is restored automatically after the
communication is restored.
If this option is disabled, a communication fault indication has to be reset manually after the
communication is restored.
Phone Fault Auto Reset
This option enables/disables the automatic phone fault reset function.
If this option is enabled, a phone fault indication is restored automatically after the phone is
restored.
If this option is disabled, a phone fault indication has to be reset manually after the phone is
restored.
General Fault Auto Reset
This option enables/disables the automatic general fault reset function.
If this option is enabled, any fault indication is restored automatically after the fault is
restored.
If this option is disabled, any fault indication has to be reset manually after the fault is
restored.
Quick Arming
This option enables/disables the quick arm function via which the user can arm the system by
pressing and holding [*] / [#] for three seconds without entering the code.
Installer Access until Next Arming
Before using installer access, a standard user has to enable installer access first. If the option
installer access until next arming is enabled, installer access permission is limited to next
arming.
Bosch Sicherheitsysteme GmbH
Installation Guide
Settings | en