1.
2.
P
–
Condition:
The keyfob is in a low battery condition if a wireless module is enabled.
Restore:
4
Supervise:
1.
2.
P
3 -Output Failure
–
Condition:
An onboard output is in a short circuit or open circuit condition.
Restore:
4
Supervise:
1.
2.
P
4 -Keypad Failure
–
Condition:
No communication between the panel and a keypad.
Restore:
4
Supervise:
1.
2.
P
5- System Failure
–
Condition:
2014.11 | 02 | F.01U.267.112
Report the sensor power fault to configured destination when the fault is detected.
Slow flash FAULT indicator (refer to Keypad Indicators, page 10 for a detailed description).
When the fault is reset, send the restored report to the configured destinations.
The FAULT indicator is turned off when there is no other system fault.
RF Keyfob Battery Failure
Restore the keyfob battery and reset the fault. For more information refer to RF Devices,
page 78.
Report the keyfob battery fault to configured destination when the fault is detected.
Slow flash FAULT indicator (refer to Keypad Indicators, page 10 for a detailed description).
When the fault is reset, send the restored report to the configured destinations.
The FAULT indicator is turned off when there is no other system fault.
Onboard Output 1-2 Fault
Restore the onboard output to a normal condition and reset the fault. For more
information refer to Outputs, page 71.
Report the onboard output 1-2 fault to configured destination when the fault is detected.
Slow flash FAULT indicator (refer to Keypad Indicators, page 10 for a detailed description).
When the fault is reset, send the restored report to the configured destinations.
The FAULT indicator is turned off when there is no other system fault.
Keypad 1-16 failure
Restore the communication between the panel and the keypad and reset the fault. For
more information refer to Keypad Area, page 65.
Report the keypad fault to the configured destination programmed on address 124.
Slow flash FAULT indicator (refer to Keypad Indicators, page 10 for a detailed description).
When the fault is reset, send the restored report to the configured destinations.
The FAULT indicator is turned off when there is no other system fault.
Date and Time not set