Keypad Indication; Keypad Lockout; System; System Setting - Bosch AMAX 2100 Installation Manual

Hide thumbs Also See for AMAX 2100:
Table of Contents

Advertisement

66
en | Settings
7.4.4

Keypad Indication

Keypad Alarm Tone
This option enables/disables the keypad alarm tone.
Audible Entry Enable
This option enables/disables a keypad warning tone during entry time when the system is in
STAY arm mode. If this option is enabled, a keypad warning tone occurs when the system is in
STAY arm mode and the entry time starts.
STAY Zone Alarm Indication
This option enables/disables the keypad alarm indication. If this option is enabled, information
is displayed on the keypad, when the system is in STAY arm mode.
Entry Delay Backlight on
This option enables/disables the keypad backlight during entry time. If this option is enabled,
the keypad backlight turns on when the system is in STAY arm mode and the entry time starts
and turns off when the entry time ends and no other button is pressed.
7.4.5

Keypad Lockout

Keypad Lock Count
The number of attempts to enter a wrong user code can be set from 1 to 15 in order to
supervise valid user access. The keypad will be locked for 3 minutes, when the number of
attempts reaches the declared value.
7.5

System

7.5.1

System Setting

This chapter describes the system settings that can be accessed via the SYSTEM SETTINGS 1
and the SYSTEM SETTINGS 2 menu and their submenus if available.
Date and Time
The AMAX panel has a 24-hour clock and a 12-month calendar that need to be set after power
up. The order is day, month, year, hour, and minute, with each item occupying two digits [DD]
[MM] [YY] [HH] [MM].
Fault Configuration
Fault Sound Reminder
When the command [2] [1] is used for fault inquiry, the keypad can be programmed to sound
prompt tone to indicate new system fault. The system is defaulted to enable. In case of a new
fault, all keypads will sound a short beep once a minute.
AC Fault Delay Time
The fault report to display on the keypad will be delayed for the selected time (01 – 98
minutes; default = 60 minutes; disabled = 99).
2014.11 | 02 | F.01U.267.112
If any zones under common zones are in triggered or tamper status and the forced arming
is disabled, the common area cannot be armed
Installation Guide
AMAX 2100 / 3000 / 4000
Bosch Sicherheitsysteme GmbH

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Amax 3000Amax 4000

Table of Contents