System Factory Default - Bosch AMAX 2100 Installation Manual

Hide thumbs Also See for AMAX 2100:
Table of Contents

Advertisement

70
en | Settings
How to display faults and tampers via a master keypad
In a master keypad the system faults and tampers are displayed directly. After an area is
selected, the area-specific faults and tampers are displayed.
How to display faults and tampers via a LED/LCD keypad
To display faults and tampers via a LED/LCD keypad, perform the following steps:
1.
2.
3.
4.
5.
6.
P
For an overview of the possible faults and tampers and how to solve them, see Trouble Fault
Inquiry, page 140.
FW Version
This option displays the current firmware version.
7.5.3

System Factory Default

The system can be reset to the factory default settings either via software or via hardware.
How to Reset the System to the Factory Default Settings via Software
Default Panel
This option resets the system to the factory settings.
4
P
Default only with Installer
This option enables/disables the possibility to reset the system via hardware. If this option is
enabled, the system can not be reset via hardware any more.
How to Reset the System to the Factory Default Settings via Hardware
The system can be reset to factory default settings with the 'resetting to factory default' pads
at the top on the printed circuit board on the main board of the AMAX panel if this possibility
is enabled in the software.
1.
2.
3.
P
2014.11 | 02 | F.01U.267.112
Enter your code + [2] [1] and press [#].
The system beeps twice. The FAULT indicator is extinguished and the STAY and AWAY
indicators flash. One of the number indicators is lit. Example: 2.
Enter the number that is lit in the system. Example: 2.
One of the number indicators is lit. Example: 1.
Repeat step 2 until there is no number lit anymore.
Refer to the table Types of fault or tamper conditions for a description of the fault or
temper. The consecutively lit number indicators correspond to fault or tamper types.
Example: 2 – 1, which indicates a panel AC failure.
If necessary press [0] to return to step 2.
Press [#] to exit.
The STAY and AWAY indicators are extinguished and the FAULT indicator is lit.
Select DEFAULT PANEL YES if you really want to reset the system or select DEFAULT
PANEL NO if you don't want to reset the system.
All programming parameters and recorded voice messages are reset to factory default.
Disconnect the AC power supply and the backup battery.
Short-circuit the 'resetting to factory default' pads.
Power up the system.
Quick flash of the red LED indicator on the printed circuit board of the AMAX panel
indicates that the factory default is reset.
All programming parameters and recorded voice messages are reset to factory default
immediately after releasing the short-circuited bonding pads.