Field Service Ver. 2.0 Apr. 2006
10.11.8

Detail on settings

A. System Input
Functions
• To select the system type for remote diagnosis.
Use
• Use to newly build or change the system.
• Select E-Mail or Modem.
Setting/
• The default setting is "E-Mail".
Procedure
B. ID Code
Functions
• To register the Service ID.
Use
• Use when registering and changing Service ID.
• Enter a 7-digit code from the 10-Key Pad. (0000001 to 9999999)
Registration
Setting/
• Touch [ID Code] and enter the Service ID.
Procedure
• Touch [ID code] to register the ID.
• The [Detail Setting] will appear when the ID has been registered.
C. Detail Setting
(1) Basic
Functions
• Execute the primary setting.
• Use to change the set contents.
Use
• Use to register the machine to the CS Remote Care Center.
1. Call the Tech. Rep. Mode to the screen.
2. Touch [CS Remote Care].
3. Touching the [Detail Setting] will display the primary setting.
Primary Setting
• Set the Center ID, Device ID, and the phone No.
• When e-mail is selected for system and all setup procedures are completed, E-mail
address of the Center is displayed.
* When entering the phone No, 10-Keys and keys on the screen have following meanings.
Setting/
[-] Pose
Procedure
[W] Wait
[T] Tone dial : Carry out tone dialing
[P] Pulse dial : Carry out pulse dialing
[*],[#]
Initial Transmission
• Touching the Initial Transmission key will sent the information to the CS Remote Care
Center to register the machine.
(Only when the Modem is selected on the system Input.)
"E-Mail"
Modem
: Waits to start transmitting after dialing
: Detects the dial tone of the other end
: To be used as necessary