Temperature/Humidity Sensor; Atdc Sensor - Konica Minolta bizhub 200 Service Manual

Bizhub 200; bizhub 250; bizhub 300
Hide thumbs Also See for bizhub 200:
Table of Contents

Advertisement

Field Service Ver. 2.0 Apr. 2006
6.3.38

Temperature/humidity Sensor

1. Remove the Upper Rear Cover.
See P.50
2. Remove the Rear Cover.
See P.51
[1]
6.3.39

ATDC Sensor

1. Select Tech. Rep. Mode → [Counter] → [Special Parts Counter] → [Developer] and
clear the counter.
2. Turn OFF the main power switch.
NOTE
• Clear the counter before removing the IU.
• After clearing the counter, be sure to turn OFF the Main Power Switch.
[3]
[2]
[6]
3. Disconnect the connector [1], widen
[2]
the two tabs [2], and remove the
Temperature/humidity Sensor [3].
[3]
[2]
4040F2C620DA
3. Open the Right Door.
[1]
4. Remove the Imaging Unit [1].
4040F2C555DA
5. Remove four screws (silver) [2] and
[2]
disassemble the Photo Conductor
Unit [3] and the Developing Unit [4].
[4]
4040F2C556DA
6. Remove three screws [5] and the
Developer Scattering Prevention
Plate [6].
[5]
4040F2C579DA
6. Other
87

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bizhub 250Bizhub 300

Table of Contents