Field Service Ver. 2.0 Apr. 2006
6.4.18

Charge Neutralizing Plate

[1]
6.4.19

Ds Collar

1. Turn OFF the main power switch.
NOTE
• Clear the PC Life counter before removing the IU.
• After clearing the PC counter, be sure to turn OFF the Main Power Switch.
[3]
[2]
[6]
1. Open the Right Door.
2. Wipe the Charge Neutralizing Plate
[1] clean of dirt with a cloth.
4040F2C553DA
2. Open the Right Door.
[1]
3. Remove the Imaging Unit [1].
4040F2C555DA
4. Remove four screws (silver) [2] and
[2]
disassemble the Photo Conductor
Unit [3] and the Developing Unit [4].
[4]
4040F2C556DA
5. Remove three screws [5] and the
Developer Scattering Prevention
Plate [6].
[5]
4040F2C579DA
6. Other