DRAFT
Theory of operation Ver. 1.0 Feb. 2010
20.3.5

Media size error detection control

• To prevent incorrect printed pages, the size of the media being conveyed is detected
using the registration sensor and media feed sensor.
• The length of the media is detected based on the value calculated using the period of
time that begins when the sensor is activated and ends when it is deactivated for each
media source.
• For the lower feeder unit, even if the media feed sensor does not detect a media size
error, the downstream registration sensor makes an error check again.
Media source
Tray 1
Tray 2
Tray 3
(Lower feeder unit)
20.3.6

Temperature/humidity sensor

• The temperature/humidity sensor detects temperature and humidity inside the main
body.
• The detected data are used for image stabilization control, ATVC control, and transfer
output control.
20. CONVEYANCE SECTION (Registration roller)
Media length detection
sensor
Registration sensor (PS4)
Registration sensor (PS4)
Media feed sensor
(PS2: Tray 3)
Registration sensor (PS4)
Starting point
Registration roller clutch
CL2: ON
Registration roller clutch
CL2: ON
Media feed sensor PS2:
ON
Registration roller clutch
CL2: ON
Ending point
Registration sensor
PS4: OFF
Registration sensor
PS4: OFF
Media feed sensor PS2:
OFF
Media feed sensor PS2:
OFF