Flueing Arrangements - Vertical Terminations - Regency PG36NG5-R Owner's Installation Manual

Pg36 gas log fireplace
Hide thumbs Also See for PG36NG5-R:
Table of Contents

Advertisement

FLUEING ARRANGEMENTS - VERTICAL TERMINATIONS

SIMPSON DURA-VENT CO AXIAL FLUE GS SYSTEM (LPG & NG)
The PG36 is approved for a 23 ft. (7.0m) vertical, with a maximum 12 ft. (3.7m) horizontal offset using
o
o
two 90
elbows (two 45
elbows equal one 90
systems for LPG and NG, as per diagram 1.
The PG36 is approved for a 37 ft. (11.3m) straight vertical, including a 20" (0.5m) horizontal offset
using two 90
o
elbow (two 45
o
elbows equal one 90
GS fl ue systems for LPG and NG, as per the diagram 2.
Flue must be supported at offsets
Maintain clearances to combustibles as listed in the "Clearances," "Locating Your Gas
Fireplace," "Combustible Mantels," "Mantel Leg Clearances" & "Framing and Finishing"
sections.
Note: Must use optional fl ue adapter when using Simpson Dura-Vent pipe
(Part # 510-994).
®
Note: Regency
Co Axial Flue System (Flex) is only approved for horizontal terminations.
®
Regency
PG36-5 Gas Log Fireplace
o
elbow) with Simpson Dura-Vent Co Axial Flue GS fl ue
o
elbow) with Simpson Dura-Vent Co Axial Flue
Diagram 1
INSTALLATION
Diagram 2
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pg36lpg5-rPg36ng4-rPg36lpg4-rPg36

Table of Contents