IMPORTANT MESSAGE

SAVE THESE INSTRUCTIONS
The PG36-NG or PG36-LPG Room Sealed
Fireplace must be installed in accordance with
AS5601-2004 and NZS 5261 5261 and these
instructions. Carefully read all the instructions
in this manual fi rst. Consult the "authority
having jurisdiction" to determine the need for
a permit prior to starting the installation. It is
the responsibility of the installer to ensure
this fi replace is installed in compliance with
manufacturer's instructions and all applicable
codes.

BEFORE YOU START

NOTE:
NOT INTENDED AS A FIREPLACE INSERT.
INSTALLATION AND REPAIR SHOULD
BE DONE BY A AUTHORISED SERVICE
PERSON. THE APPLIANCE SHOULD
BE INSPECTED BEFORE USE AND AT
LEAST ANNUALLY BY AN AUTHORISED
SERVICE PERSON. MORE FREQUENT
CLEANING MAY BE REQUIRED
DUE TO EXCESSIVE LINT FROM
CARPETING, BEDDING MATERIAL,
ETC. IT IS IMPERATIVE THAT CONTROL
COMPARTMENTS, BURNERS AND
CIRCULATING AIR PASSAGEWAYS
OF THE APPLIANCE BE KEPT CLEAN.
DUE TO HIGH TEMPERATURES, THE
APPLIANCE SHOULD BE LOCATED
OUT OF TRAFFIC AND AWAY FROM
FURNITURE AND DRAPERIES.
WARNING: FAILURE TO INSTALL THIS
APPLIANCE CORRECTLY WILL VOID
YOUR WARRANTY AND MAY CAUSE A
SERIOUS HOUSE FIRE.
CHILDREN AND ADULTS SHOULD
BE ALERTED TO THE HAZARDS OF
HIGH SURFACE TEMPERATURES,
ESPECIALLY THE FIREPLACE GLASS,
AND SHOULD STAY AWAY TO AVOID
BURNS OR CLOTHING IGNITION.
YOUNG CHILDREN SHOULD BE
CAREFULLY
SUPERVISED WHEN
THEY ARE IN THE SAME ROOM AS THE
APPLIANCE.
CLOTHING OR OTHER FLAMMABLE
MATERIAL SHOULD NOT BE PLACED
ON OR NEAR THE APPLIANCE. DO NOT
USE AEROSOLS IN THE VICINITY OF
THIS APPLIANCE.
®
Regency
PG36-5 Gas Log Fireplace
GENERAL SAFETY
INFORMATION
1) The appliance shall be installed in
accordance with the manufacturer's
installation instructions,local gas fi tting
regulations, municipal building codes,
water supply regulations, electrical wiring
regulations, with AS5601-2004 (AGA gas
installation code) NZS 5261 (New Zealand)
2) Installation and repair should be done
ONLY by an authorised person.
3) THIS APPLIANCE IS NOT INTENDED AS A
FIREPLACE INSERT. DO NOT CONNECT
TO MASONARY FLUE.
4) This appliance must be connected to
the specifi ed fl ue and termination cap
to the outside of the building envelope.
Never fl ue to another room or inside a
building. Make sure that the fl ue is fi tted
as per Flueing instructions.
5) Inspect the fl ueing system annually for
blockage and any signs of deterioration.
6) Flueing terminals shall not be recessed into
a wall or siding.
7) Any safety glass removed for servicing must
be replaced prior to operating the appliance.
8) To prevent injury, do not allow anyone who
is unfamiliar with the operation to use the
fi replace.
9) Wear gloves and safety glasses for protection
while doing required maintenance.
10) Be aware of electrical wiring locations in
walls and ceilings when cutting holes for
termination.
11) Under no circumstances should this
appliance be modifi ed. Parts that have to be
removed for servicing should be replaced
prior to operating this appliance.
12) Installation and any repairs to this appliance
should be done by an authorised service
person. An authorised service person should
be called to inspect this appliance annually.
Make it a practice to have all of your gas
appliances checked annually.
13) Do not slam shut or strike the glass door.
14) Under no circumstances should any solid
fuels (wood, paper, cardboard, coal, etc.)
be used in this appliance.
15) The appliance area must be kept clear and
free of combustible materials, (gases and
other fl ammable vapours and liquids).

INSTALLATION

INSTALLATION
CHECKLIST
1) Locate appliance. Refer to the following
sections:
a) Locating Your Gas Fireplace
b) Combustible Mantels
c) Mantel Leg Clearances
d) Framing and Finishing
e) Flueing
2) Assemble Top Standoffs and Top Facing
Support and Side Nailing Strips. Refer to the
"Unit Assembly Prior to Installation" section.
(NOTE: must be done before installing unit
into fi replace.)
3) Install flue, refer to the "Horizontal
Termination" & "Vertical Termination"
sections.
4) Make gas and electrical connections. Test
the pilot. Must be as per diagram. Refer to
the " Pilot Adjustment" section.
5) Install standard and optional features. Refer
to the following sections where applicable:
a. Brick Panels
b. Log Set Installation
c. Flush Door
d. Premium Flush Front
e. Bay Door
f. Hampton Cast Faceplate
g. Hampton Cast Grills
h. Remote Controls
6) Final check.
Before leaving this unit with the customer,
the installer must ensure that the appliance is
fi ring correctly and operation fully explained
to customer.
This includes:
1) Clocking the appliance to ensure the correct
fi ring rate (rate noted on label 30,000 Btu/h)
after burning appliance for 15 minutes.
2) If required, adjusting the primary air to ensure
that the fl ame does not carbon. First allow
the unit to burn for15-20 min. to stabilize.
CAUTION: Any alteration to the product that
causes sooting or carboning that results
in damage is not the responsibility of the
manufacturer.