INSTALLATION
The PG36 is approved for a 37 ft. (11.3m) straight vertical, with Simpson
Dura-Vent Co Axial Flue GS fl ue systems for LPG and NG, as per the
diagram 3.
The shaded area in the diagram 3 shows all allowable combinations of straight
vertical and offset to vertical terminations with Simpson Dura-Vent Co Axial
Flue GS fl ue systems for LPG and NG. Maximum two 45
Flue must be supported at offsets
Firestops are required at each fl oor level and whenever passing
through a wall.
Maintain clearances to combustibles as listed in the "Clearances,"
"Locating Your Gas Fireplace," "Combustible Mantels," "Mantel Leg
Clearances" & "Framing and Finishing" sections.
16
o
elbows allowed.
Diagram 3
®