FLUEING ARRANGEMENTS - VERTICAL TERMINATIONS

SIMPSON DURA-VENT CO AXIAL FLUE GS SYSTEM (LPG & NG)
The PG36 is approved for a 23 ft. (7.0m) vertical, with a maximum 12 ft. (3.7m) horizontal offset using
two 90
elbows (two 45
elbows equal one 90
o
o
systems for LPG and NG, as per diagram 1.
The PG36 is approved for a 37 ft. (11.3m) straight vertical, including a 20" (0.5m) horizontal offset
using two 90
elbow (two 45
elbows equal one 90
o
o
GS flue systems for LPG and NG, as per the diagram 2.
Flue must be supported at offsets
Maintain clearances to combustibles as listed in the "Clearances," "Locating Your Gas
Fireplace," "Combustible Mantels," "Mantel Leg Clearances" & "Framing and Finishing"
sections.
Note: Must use optional flue adapter when using Simpson Dura-Vent pipe
(Part # 510-994).
Note: Regency
Co Axial Flue System (Flex) is only approved for horizontal terminations.
®
Regency
PG36-5 Gas Log Fireplace
®
elbow) with Simpson Dura-Vent Co Axial Flue GS flue