LISTINGS AND CODE APPROVALS
These gas appliances have been tested
in accordance with AS4533-2000, NZS
5262 and have been certified by the
Australian Gas Association for installa-
tion and operation as described in these
Installation and Operating Instructions.
Your unit should be serviced annu-
ally by an authorised service person.
PG33 Gas Inbuilt
PLEASE KEEP THESE INSTRUCTIONS
FOR FUTURE REFERENCE
WARNING:
Improper installation, adjustment, altera-
tion, service or maintenance can cause
injury or property damage. Refer to this
manual. For assistance or additional in-
formation consult an authorised installer,
service agency or the gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other flam-
mable vapours and liquids in the vicinity of
this or any other appliance.
Installation and service must be performed
by an authorised installer, service agency or
the gas supplier.
918-649c
Models:
PG33-NG
PG33-LPG
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appli-
ance
Do not touch any electri-
cal switch: do not use any
phone in your building.
Immediately call your gas
supplier from a neighbour's
phone. Follow the gas sup-
plier's instructions.
If you cannot reach your
gas supplier, call the fire
department.
04/08/15

Advertisement

Table of Contents
loading

Summary of Contents for Regency PG33-NG

  • Page 1 Owners & Installation PG33 Gas Inbuilt Models: PG33-NG PG33-LPG PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING: FOR YOUR SAFETY Improper installation, adjustment, altera- What to do if you smell gas: tion, service or maintenance can cause Do not try to light any appli- LISTINGS AND CODE APPROVALS injury or property damage.
  • Page 2: To The New Owner

    PG33 has been approved by the Australian Gas Association for both safety and efficiency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow. Please take a moment now to acquaint yourself with these instructions and the many features of your Regency Fireplace.
  • Page 3: Table Of Contents

    Flueing Introduction ............ 9 Gold-Plated or Brass Louvers ........33 Exterior Flue Termination Locations ......10 Gold Plated or Brass Trim ........33 Flueing - Regency Direct Flue System (Flex) Log Replacement ............. 33 Horizontal Terminations only ........11 Glass Gasket ............34 Flueing - Installation of Regency Direct Flue Door Glass..............
  • Page 4: Safety Label

    This is a copy of the label that accompanies each PG33 Gas Fireplace. We have printed a copy of the contents here for your review. DATA BADGE NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
  • Page 5: Installation

    SHOULD STAY AWAY TO AVOID BURNS 8) To prevent injury, do not allow anyone who is OR CLOTHING IGNITION. unfamiliar with the operation to use the fireplace. 9) Wear gloves and safety glasses for protection while doing required maintenance. Regency PG33 Gas Inbuilt...
  • Page 6: Installation Checklist

    4) The PG33 can be installed in a recessed position or framed out into the room as in A, B, C, D. See Diagram 1. 5) This appliance is Listed for bedroom instal- Regency PG33 Gas Inbuilt...
  • Page 7: Clearances

    Note: Ensure the paint that is used on the mantel and the facing is "heat resistant" or the paint may discolour. The clearances listed below are Minimum dis- tances unless otherwise stated: 1-1/2" (38mm) projection at 2" (51mm) minimum clearance. Clearances for Bay or Flush Front Regency PG33 Gas Inbuilt...
  • Page 8: Framing And Finishing

    For Both Simpson & Flex Minimum connection NOTE: If this is an outside corner, the minimum distance between the flue and the outside corner is 6" (15cm) with AstroCap termination cap or 12" (30cm) with Dura-Flue termination cap. Regency PG33 Gas Inbuilt...
  • Page 9: Unit Assembly Prior To Installation

    There are 2 flue systems approved for use with the PG33: the Regency Direct Flue System (Flex) for Horizontal Terminations only (see pages 11- 12), and the Simpson Dura-Flue Systems for Horizontal and Vertical Terminations (see pages 13-25).
  • Page 10: Exterior Flue Termination Locations

    (IV) A flue terminal of this type shall not be located under a roofed area unless the roofed area is fully open on at least two sides and a free flow of air at the appliance is achieved. Regency PG33 Gas Inbuilt...
  • Page 11: Horizontal Terminations Only

    Flue Terminal Locations diagram on page 10. Regency Direct Flue (Flex) System Termination Kit (Part # 946-513) includes all the parts needed to install the PG33 with a maximum run of 2 feet.
  • Page 12: Installation Procedures

    INSTALLATION INSTALLATION PROCEDURES for Regency Direct Flue System (Flex) 1) Locate the unit in the framing, rough in the gas (preferably on the right side of the unit) and the electrical (Junction block is on the left side) on the left. Locate the centerline of the termination and mark wall accordingly.
  • Page 13: Horizontal Or Vertical Terminations

    Wall Thimble tions using FPI flueing systems as well as Simpson Dura-Vent® and Direct Vent GS. Adj.Pipe Length 11" - 14-5/8" Regency , and Regency AstroCap are the (279mm - 372mm) proprietary trademarks of FPI Fireplace Products 45 Elbow International Ltd.
  • Page 14 Flue must be supported at offsets. • Firestops are required at each floor level and whenever passing through a wall. • Maintain clearances to combustibles. Note: Must use optional flue adapter when using Simpson Dura-Vent pipe (Part # 510-994). Regency PG33 Gas Inbuilt...
  • Page 15 GS flue systems for LPG, ULPG and NG. Maximum two 45 elbows allowed. 11.6 • Flue must be supported at offsets. • Firestops are required at each floor level and whenever passing through a wall. • Maintain clearances to combustibles. 10.4 Regency PG33 Gas Inbuilt...
  • Page 16 Note: Must use optional flue adapter (Part # 510-994) when using Simpson Dura-Vent pipe. (Refer to page 13.) Horizontal (M) A flue guard should be used whenever the termination is lower than the specified minimum or as per local codes. Note: Regency Direct Flue System (Flex) is only approved for horizontal termina- tions. 30” (762mm) Minimum •...
  • Page 17 2’ (0.6m) A flue guard should be used whenever the termination is lower than the specified minimum or as per local codes. Note: Regency Direct Flue System (Flex) is only ap- proved for horizontal terminations. • Maintain clearances to combustibles.
  • Page 18 0.6m Max. 0.9m Min. 1.5m Max. total horizontal. 0.9m Max. 1.5m Min. 1.8m Max. Please note min. 1 foot between 90 elbows is 1.2m Max 1.8m Min 2.1m Max. required. 1.5m Max 2.4m Min. 2.4m Max. Regency PG33 Gas Inbuilt...
  • Page 19 1.2m 1.2m between 90 elbows is between 90 elbows is re- 1.2m 2.1m 1.5m 1.5m 1.5m required. quired. 1.5m 2.4m 1.8m 1.8m 1.8m For additional vertical flueing with 2 x 90 elbows, refer to page 15. Regency PG33 Gas Inbuilt...
  • Page 20 1.2m of 10 feet total vertical and 0.9m 1.2m 1.8m max. 8 feet total horizontal. 1.2m 1.5m 2.1m Please note min. 1 foot between 90 elbows is 1.5m 1.8m 2.4m required. 1.8m 2.1m 2.7m 2.1m 2.4m Regency PG33 Gas Inbuilt...
  • Page 21: Horizontal Installations

    Cut and frame the 10 inch square mination is not recessed into the siding. 7) Before connecting the horizontal run of flue pipe to the flue termination, slide the Wall Thimble (Part # 620-926) over the flue pipe. Regency PG33 Gas Inbuilt...
  • Page 22: Vertical Termination

    3' (0.9m), to avoid excessive stress on the el- bows, and possible separation. Wall straps are available for this purpose. Galvanized pipe is desirable above the roofline due to its higher corrosion resistance. Continue Diagram 2 Regency PG33 Gas Inbuilt...
  • Page 23: System Data

    INSTALLATION GAS CONNECTION 7) Gas Outlet Pressure Electric Modulator PG33-NG System Data 8) Pilot Outlet 9) Main Gas Outlet The gas line should be rigid pipe. Copper may Conversion Kit# 433-968 also be used if approved by AS5601-2004. 10) Side Outlet For 0 to 610 metres altitude The gas connection at the valve is 1/2 Female.
  • Page 24 INSTALLATION Conversion Kit #433-968 for NG to LPG THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Regency PG33 Gas Inbuilt...
  • Page 25 INSTALLATION Regency PG33 Gas Inbuilt...
  • Page 26: Optional Brick Panels

    3) Place the Log 250 on the rear log support 5) Slide the Top Brick Panel into position and slide the Top Brick Retaining clips so that they hold the Top Brick Panel in place and tighten down the screws. 2nd Grate Tab Regency PG33 Gas Inbuilt...
  • Page 27: Flush Louvers

    Flush door. bracket down onto the 2 pins on the base of the unit (dia. 1). Secure with 1 screw as per diagram 2. Note: Top and bottom louvers are different. 5th Grate Tab Regency PG33 Gas Inbuilt...
  • Page 28 Diagram 2. Diagram 1 Diagram 2 Regency PG33 Gas Inbuilt...
  • Page 29 This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug. Regency PG33 Gas Inbuilt...
  • Page 30: Lighting Plate Instructions

    DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IN OPERATION. Colours: Black on Grey, except for parts indicated as being Red. Size: 100% Feb. 8/06: Changed AG 601 to AS5601-2004 as per Paul Watters. Regency PG33 Gas Inbuilt...
  • Page 31: Resetting The Unit

    REMOTE CONTROL SHUTDOWN OPERATING INSTRUCTIONS INSTRUCTIONS Use the Regency Remote Control Kit approved for this unit. Use of other systems may void your 1) Press the ON/OFF button once. Before operating this appliance, proceed through warranty. the following check list.
  • Page 32: Fan Operation

    Blower: Periodically check the pilot flames. The correct Regency gas appliances use high tech blowers flame pattern has 3 strong blue flames. to push heated air farther into the room. It is not unusual for the fan to make a "whirring" sound One flowing around the thermocouple, the when ON.
  • Page 33: Maintenance Instructions

    CIAN TO INSPECT THE APPLI- heat resistant paint (not with wall paint). 4) Inspect joints, to verify that no pipe sections or Regency uses StoveBright Paint - Metallic fittings have been disturbed, and consequently ANCE AND TO REPLACE ANY Black #6309.
  • Page 34: Gold-Plated Or Brass Louvers

    Clean any fingerprints off before turning the unit on. Your Regency stove is supplied with high temperature, 5 mm Neoceram ceramic glass that will withstand the highest heat that your unit will produce.
  • Page 35: Fan Replacement

    5) Unplug the 6 pin Molex connector and carefully pull out the ECS 11) Reverse steps to install new fan. box. ECS Box 6 Pin Molex Connector 6) Remove the electric cover by undoing the 2 screws, pull out the grommet and the harness. Electric Cover Regency PG33 Gas Inbuilt...
  • Page 36: Removing Valve Tray

    Rear Log Stand 7) Disconnect the inlet gas line. Valve Tray Assembly 12) To replace the burner tray assembly reverse these instructions. 13) Check for any gas leaks. 14) Check for proper flame appearance and glow on logs. Regency PG33 Gas Inbuilt...
  • Page 37: Parts List

        910-527 Manual Control Switch    910-935 Manual Control Switch      *Note: The Control Box Cable wires for the FG38 come separately: 910-502, 910-505, 910-506, 910-507, 910-509 Regency PG33 Gas Inbuilt...
  • Page 38: Main Assembly

    Oval Duct Adaptor 28) * Inner Flue Collar Assembly 93) 946-007 Angle Bracket 30) * Gasket - Flue Collar 95) 946-006 Grill Plate - White 31) * Flue Mounting Plate 96) 946-005 Wall Adaptor Plate - White Regency PG33 Gas Inbuilt...
  • Page 39 Burner Grate Assembly - NG / LPG 83) * Rear Log Support Bracket - NG / LPG 85) 431-930 Log Set 86) 430-097 Air Deflector - Left 87) 433-018 Air Deflector - Right *Not available as a replacement part. Regency PG33 Gas Inbuilt...
  • Page 40 Flush Door Assembly Complete 135) 940-088/P Glass (Flush) 137) 904-691 U-Clip 139) 936-155 Glass Gasket (Tadpole) 140) 948-042 Spring Hinge - Black 430-940 Finishing Trim (Set) - Black (Option) 157) * Finishing Trim Left 159) * Finishing Trim Right Regency PG33 Gas Inbuilt...
  • Page 41 NOTES Regency PG33 Gas Inbuilt...
  • Page 42: Warranty

    ® Regency shall in no event be liable for any special, indirect consequential damages of any nature whatsoever which are in excess of the original purchase price of the product. Any alteration to the unit which causes sooting or carboning that results in damage to the exterior facia is not the responsibility of Regency Fireplace Products.
  • Page 43 03 9799 7277 NOTE: PLEASE RETAIN YOUR INVOICE AS PROOF OF PURCHASE FOR WARRANTY VERIFICATION INCORRECT INSTALLATION OR GAS PRESSURE SETTINGS ARE NOT COVERED BY WARRANTY A SERVICE OR CALLOUT FEE WILL BE CHARGED IN THESE CIRCUMSTANCES. Regency PG33 Gas Inbuilt...
  • Page 44 Register your Regency warranty online ® www.regency-fire.com.au Reasons to register your product online today! • View and modify a list of all your registered products. • Request automatic email notification of new product updates. • Stay informed about the current promotions, events, and special offers on related products.