INSTALLATION
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION!!
LPG Conversion Kit Contains:
Qty.
Part #
Description
1
904-390
Burner Orifi ce #52
1
904-529
5/32" Allen Key
1
918-590
Label "Converted to LP"
1
908-528
Red "LPG" label
1
910-037
#30 ULPG Pilot Orifi ce
1
918-577
Instruction Sheet
1)
Shut off the gas supply and unplug the
power cord.
2)
Carefully remove the glass, logs and
lava rock.
3)
Remove burner.
4)
Remove burner orifi ce with a 1/2"
wrench and discard. Use a wrench to
hold on to the elbow behind the orifi ce.
5)
Reinstall new burner orifi ce stamped #52
and tighten.
6)
Pull out the pilot hood by hand.
Pilot
Hood
20
Conversion From NG To LPG Kit #513-968
Pilot
Hood
removed
Pilot
Orifi ce
7)
Remove the pilot orifi ce with the allen
key.
8)
Put in the new LPG orifi ce with the allen
key. Then put back the pilot hood.
Burner Orifi ce
9)
Adjust the burner aeration setting to and
re-install the burner.
10) Open the bottom louver.
11) Remove the front cover by undoing the 2
screws.
Front Cover
12) Stick the conversion label "This unit has
been converted to LPG" over top of the
serial number decal.
13) Replace the yellow "NG" label with the
red "LPG" label.
14) Carefully pull out the control box from
underneath the fi rebox.
Note: The control box is held in place with
velcro.
®
Regency
PG36-5 Gas Log Fireplace

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pg36lpg5-rPg36ng4-rPg36lpg4-rPg36

Table of Contents