Regency Panorama P33-10 Owners & Installation Manual

Zero clearance direct vent gas fireplace
Table of Contents

Advertisement

Quick Links

Panorama
Direct Vent Gas Fireplace
MODELS:
P33-NG10 Natural Gas
WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious
injury, death, or property damage.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
• Do not touch any electrical switch: do not use any phone in your building.
Leave the building immediately.
• Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's
instructions.
• If you cannot reach you gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Tested by:
919-392a
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.
P33-10 Zero Clearance
®
P33-LP10 Propane
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
6988 Venture St., Delta, BC Canada, V4G 1H4
Owners &
Installation Manual
www.regency-fire.com
09.15.15

Advertisement

Table of Contents
loading

Summary of Contents for Regency Panorama P33-10

  • Page 1 Panorama P33-10 Zero Clearance ® Owners & Direct Vent Gas Fireplace Installation Manual www.regency-fire.com MODELS: P33-NG10 Natural Gas P33-LP10 Propane WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage.
  • Page 2 The P33-10 has been approved by Intertek for both safety and efficiency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow. Please take a moment now to acquaint yourself with these instructions and the many features of your Regency Fireplace.
  • Page 3 INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE This Regency product has been tested and listed by Warnock Hersey/Intertek as a Direct Vent Wall Furnace to the following standards: ® VENTED GAS FIREPLACE HEATERS ANSI Z21.88-2014 • CSA 2.33-2014 and GAS-FIRED APPLIANCES FOR USE AT HIGH ALTITUDES CAN/CGA-2.17-M91.
  • Page 4: Table Of Contents

    Shutdown Procedure ..........47 Venting Introduction ........... 16 First Fire ..............47 Exterior Vent Termination Locations ......17 Aeration Adjustment ..........48 Regency Direct Vent flex System ......18 Normal Operating Sounds of Gas Appliances ... 48 ® Installation Procedures ..........19 Maintenance Instructions ..........
  • Page 5: Safety Label

    The safety label is located on the front inside base of the unit, visible when the bottom louver is open. NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
  • Page 6: For The State Of Massachusetts Only

    (e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipm ent, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 7: Unit Dimensions With Vignette Faceplate And Finishing Trim

    UNIT DIMENSIONS WITH VIGNETTE FACEPLATE AND FINISHING TRIM NOTE: Vignette Faceplate without Trim: 27-1/4"H x 30-3/4" W Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 8: Unit Dimensions With Vignette And Vignette Finishing Trim

    UNIT DIMENSIONS WITH VIGNETTE AND VIGNETTE FINISHING TRIM UNIT DIMENSIONS WITH SAFETY SCREEN (#439-929) AND OPTIONAL LOUVERS Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 9: Important Message

    National Electrical Code, ANSI/NFPA 70 or CSA C22.1 Canadian Electrical Code. Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 10: Installation Checklist

    15-20 min. to stabilize. CAUTION: Any alteration to the product that Diagram 1 causes sooting or carboning that results in damage is not the responsibility of the manufacturer. 10 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 11: Clearances With Vignette Faceplate

    * see mantel clearance instructions. MANTEL LEG CLEARANCES WITH FLUSH GLASS Combustible mantel leg clearances from side of unit as per diagram: Maximum 1-1/2" projection at 2" minimum clearance. Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 12: Combustible Mantels

    MANTEL CLEARANCES WITH VIGNETTE + VIGNETTE ONLY (No Vignette Finishing Trim) VIGNETTE FINISHING TRIM STEPPED FINISH MANTEL CLEARANCES WITH MANTEL CLEARANCES WITH VIGNETTE + VIGNETTE FINISHING TRIM SAFETY SCREEN AND LOUVERS FLUSH FINISH 12 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 13: Wall Mount On / Off Switch Installation

    6" (15cm) with AstroCap termination cap or is 6" (15cm) with AstroCap termination cap or 12" (30cm) with Rigid Vent termination cap. (For 12" (30cm) with Rigid Vent termination cap. (For example Dura-Vent). Example Dura-Vent). Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 14: Framing And Finishing

    6) Use steel studs for framing where the 1-1/2" (38mm) clearance from the vent to combustible material cannot be maintained. The HeatWave Duct Kit has different clearance and framing requirements, check the HeatWave manual for details. 14 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 15: Remote Receiver Installation

    11. Using the two (2) screws provided secure the cover plate to the Receiver. Low Voltage Junction Box Profl ame Receiver J-Box Receiver Slider Switch Wall Plate 10 ft. wire harness with 12 pin connector Diagram 1 Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 16: Unit Assembly Prior To Installation

    There are 5 vent systems approved for use with the P33-10: the Regency Direct Vent Flex System for Horizontal Terminations only and the Simpson Dura- ®...
  • Page 17: Exterior Vent Termination Locations

    * Clearance in accordance with local installation codes and the requirements of the gas supplier 3 feet (91cm) within a height of 15 feet (4.5m) above the meter / regulator assembly 3 feet (91cm) above - if within 10 feet (3m) horizontally Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 18: Regency ® Direct Vent Flex System

    (Part# 946-523/P) Notes: spring 1) Liner sections should be continuous spacer without any joints or seams. 2) Only Flex pipe purchased from Regency ® 6-7/8" may be used for Flex installations. See Figure 1 below for (173mm) Alternate Caps.
  • Page 19: Installation Procedures

    INSTALLATION PROCEDURES for Regency Direct Vent System (Flex) ® 1) Locate the unit in the framing, rough in the *If this is an outside corner, the minimum distance between the vent and the outside gas (preferably on the right side of the unit) corner is 6"...
  • Page 20: Rigid Pipe Venting Systems

    , Selkirk Direct-Temp. AstroCap is a proprietary trademark of FPI Fireplace ® Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc. 20 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 21: 4" X 6-5/8" Rigid Pipe Cross Reference Chart

    4DFSP 4DFS SV4BF TM-4CS Trim Plate-Black 4DT-TP 4DFPB 4DcP SV4LA TM-4TP Regency Fireplace Products . 6988 Venture St. . Delta, BC . Canada . V4G 1H4 . 604-946-5155 . www.regency-fi re.com Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 22 Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard. Regency Fireplace Products . 6988 Venture St. . Delta, BC . Canada . V4G 1H4 . 604-946-5155 . www.regency-fi re.com...
  • Page 23: Rigid Pipe Venting Arrangements

    Firestops are required at each floor level and whenever passing through a wall. • Maintain clearances to combustibles. Note: Must use optional rigid pipe adapter when using rigid vent systems (Part # 510-994). Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 24 Propane and Natural Gas. Maximum two 45 elbows allowed. • Vent must be supported at offsets. • Firestops are required at each floor level and whenever passing through a wall. • Maintain clearances to combustibles. 24 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 25: Horizontal Terminations

    Note: Must use optional rigid pipe adaptor (Part # 510-994) when using rigid pipe vent systems. (Refer "Rigid Pipe Venting Systems" Section) A vent guard should be used whenever the termination is lower than the specified minimum or as per local codes. Note: Regency Direct Vent System (Flex) ® is only approved for horizontal terminations.
  • Page 26 3' Max. 4' Min. 6' Max. Please note minimum 4' Max. 6' Min. 7' Max. 1 foot between 90 elbows is required. 5' Max. 8' Min. 8' Max. 26 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 27 1 foot between 90 6' Max. 6' Min. elbows is required. 5' Min. 8' Max. 6' Min. For additional vertical venting with 2 x 90 elbows, refer to "Rigid Pipe Venting Arrangements" Section. Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 28 5' Min. 6' Max. 8' Min. Please note min. 1 foot 6' Min. 7' Max. 9' Min. between 90 elbows is required. 7' Min. 8' Max. 10' Min. 28 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 29: Vertical Termination With Co-Linear Flex System In A Masonry Chimney

    3" Co-linear Adapter with flashing Outer Pipe with Kit# 946-563 Air Intake Pipe Length Co-Linear Flex Rigid Pipe Adapter Adapter # 510-994 with Kit# 946-563 45 Elbow Inner Pipe Adapter with Kit# 946-563 Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 30: Venting Arrangements - Vertical Terminations

    VENTING ARRANGEMENTS - VERTICAL TERMINATIONS with Co-linear Flex System for both Residential & Manufactured Homes into Masonry Fireplaces Horizontal Distance (Feet) The shaded area in the diagrams show the allowable vertical terminations. 30 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 31: Unit Installation With Horizontal Termination

    Failure to do so may result in pipe to the vent termination, slide the Wall drafting or performance issues not covered Thimble (Part # 620-926) over the vent under warranty. pipe. Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 32: Unit Installation With Vertical Termination

    Do not use open flame for leak testing. slide storm collar over the pipe section and Diagram 2 seal with a mastic. 32 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 33: Pilot Adjustment

    2) Electronically Operated Hi/Lo 3) Pilot Adjustment 4) Thermocouple Connection - option 5) Outlet Pressure Tap 6) Inlet Pressure Tap 7) Pilot Outlet 8) Main Gas Outlet 9) Alternative TC Connection Point Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 34: Conversion From Ng To Lp

    Assembly to the left and lift out. label. 15. Check operation of flame control. 16. Check for proper flame appearance and glow on logs. Burner Orifice Reinstall new burner orifice LPG stamped #55 and tighten. Installer Notice: These instructions must be left with the appliance. 34 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ® 10.17.14 919-466...
  • Page 35: Optional Brick Panels

    5) Slide the Top Brick Panel into position and slide the Top Brick Retaining clips so that they hold the Top Brick Panel in place and tighten down the screws. 2nd Grate Tab Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 36: Standard Flush Door

    See Diagram 2. 5th Grate Tab 36 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 37: Optional Wall Thermostat

    Note: Preferable if the thermostat is installed 16 GA. 32 Ft. on an interior wall. 18 GA. 20 Ft. Regency offers an optional programmable ® 20 GA. 12 Ft. thermostat but any 250-750 millivolt rated non- 22 GA.
  • Page 38: Wiring Diagrams

    CAUTION: Label all wires not touch any hot surfaces and are prior to disconnection away from sharp edges. when servicing controls. Wiring errors can cause improper and dangerous operation. 38 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 39: Optional Wall Thermostat Installation

    Unit will now operate using the wall thermostat. nector - see picture below. NOTE: When the remote receiver is set to ON position, the remote control transmitter and all of its features are now dis- abled. Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 40: Installing The Optional Fan

    THESE FANS COLLECT A LOT OF DUST FROM WITHIN YOUR HOME. ENSURE YOU MAINTAIN THESE FAN MOTORS ON A REGULAR BASIS BY VACUUMING THE FAN BLADES AND THE HOUSING WITH A SOFT BRUSH NOZZLE. 40 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ® 919-474 10.29.14...
  • Page 41: Vignette Faceplate And Safety Screen Install

    Vignette frame (see below). Screen below. assembly is secured at bottom with magnets. Screen Assembly Vignette Frame Reverse Steps to remove. Secure Vignette frame using 2 screws in locations shown below. Final Install Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ® 12.03.14 919-468...
  • Page 42: Optional Vignette Finishing Trim

    Hook Vignette Faceplate brackets into place. Line up the screw holes on the fi nishing trim and Vignette Face- plate bracket with the unit–fasten with one screw on each side– P33 only. 05.04.15 919-566 42 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 43: Optional Vignette Inlay Installation

    NOTE: Ensure Inlay is in correct position before pushing studs through the safety screen. Stud Nut + washer (supplied) Completed Install Line up Inlay–Push studs on Inlay through screen Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ® 05.21.15 919-559...
  • Page 44: Optional Finishing Trim

    Line up the screw holes on the finishing trim and Vignette Faceplate bracket with the unit–fasten with one screw on each side. Reinstall the glass door and safety screen. Finishing Trim Top Finishing Trim Side 44 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ® 10.29.14 919-475...
  • Page 45: Optional Louvers

    4. Install bottom louver assembly by opening bottom louver enough to tighten screws. allow access to attach bottom louver brackets to unit with one screw on each side in locations shown below. Magnet locations 07.21.15 919-558a Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 46: Copy Of The Lighting Plate Instructions

    Mettre le bouton de contrôle de gaz sur ''OFF'' pour éteindre la veilleuse. Pour économiser le carburant, éteindre la veilleuse quand l’appareil reste longtemps inutilisé. DO NOT REMOVE THIS INSTRUCTION PLATE 919-456 46 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 47: Operating Instructions

    NEVER clean Button the glass while it is hot. Proflame video Diagram 2 Remote shown in Manual Mode on Hi 6. The unit will turn on. Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 48: Aeration Adjustment

    NOT covered under warranty. Unit Body/Firebox: Note: Aeration Adjustment should only be Different types and thicknesses of steel will expand performed by an authorized Regency ® and contract at different rates resulting in some Installer at the time of installation or "cracking"...
  • Page 49: General Vent Maintenance

    (The DOOR GLASS pilot light generates enough heat to burn someone.) If for any reason a log should need replacement, you Your Regency fireplace is supplied with high ® must use the proper replacement log. The position...
  • Page 50: Removing Valve

    Hint: If you are using black pipe, ensure that there is a union by the valve, otherwise removal will be almost impossible. screws Rear Log Stand Diagram 2: Rear Log Stand 50 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 51: Main Assembly

    Brick Panel - Top 430-056 Brick Clip - Top 430-057 Brick Clip - Bottom 438-917 Fan Assembly (120 Volts) Optional 910-331/P Fan Motor (120 Volts) 910-813 Power Cord (120 Volts) Part # Description Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 52: Parts List

    HEAT WAVE DUCT KIT #946-556 BRICK PANEL SET FAN ASSEMBLY 52 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 53: Burner & Log Assembly

    Pilot Tube w/nuts 910-073 DC spark box 910-074 DC spark box wire 911-030 Fan Control Module 439-969 Conversion Kit LP 911-032 Valve/Remote Wiring Harness 433-020 Pilot Shield *Not available as a replacement part. Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 54: Vignette Faceplate And Finishing Trim

    Vignette Faceplate Tuscan Sunset 439-948 Vignette Door Inlay Black Chrome 439-949 Vignette Door Inlay Mt. Black 430-940 3 sided Finishing Trim 439-950 Vignette Door Inlay Tuscan Sunset Parts Not Shown 54 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 55: Safety Screen And Louvers

    SAFETY SCREEN AND LOUVERS Part # Description 439-920 Flush louvers black 439-929 Safety Screen Regency Logo Plate 948-216 ® Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 56 56 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 57 Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 58 58 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 59: Warranty

    Conditions: Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced at Regency's option, through an accredited distributor or agent provid- ed that the defective part be returned to the distributor or agent Transportation Prepaid, if requested.
  • Page 60 Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ Regency, Panorama, AstroCap are trademarks of FPI Fireplace Products International Ltd. © Copyright 2015, FPI Fireplace Products International Ltd. All rights reserved. Printed in Canada...

Table of Contents