Zero clearance direct vent gas fireplace (64 pages)
Summary of Contents for Regency Panorama P33-10
Page 1
Panorama P33-10 Zero Clearance ® Owners & Direct Vent Gas Fireplace Installation Manual www.regency-fire.com MODELS: P33-NG10 Natural Gas P33-LP10 Propane WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage.
Page 2
The P33-10 has been approved by Intertek for both safety and efficiency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow. Please take a moment now to acquaint yourself with these instructions and the many features of your Regency Fireplace.
Page 3
INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE This Regency product has been tested and listed by Warnock Hersey/Intertek as a Direct Vent Wall Furnace to the following standards: ® VENTED GAS FIREPLACE HEATERS ANSI Z21.88-2014 • CSA 2.33-2014 and GAS-FIRED APPLIANCES FOR USE AT HIGH ALTITUDES CAN/CGA-2.17-M91.
The safety label is located on the front inside base of the unit, visible when the bottom louver is open. NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipm ent, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
UNIT DIMENSIONS WITH VIGNETTE FACEPLATE AND FINISHING TRIM NOTE: Vignette Faceplate without Trim: 27-1/4"H x 30-3/4" W Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
UNIT DIMENSIONS WITH VIGNETTE AND VIGNETTE FINISHING TRIM UNIT DIMENSIONS WITH SAFETY SCREEN (#439-929) AND OPTIONAL LOUVERS Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
15-20 min. to stabilize. CAUTION: Any alteration to the product that Diagram 1 causes sooting or carboning that results in damage is not the responsibility of the manufacturer. 10 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
* see mantel clearance instructions. MANTEL LEG CLEARANCES WITH FLUSH GLASS Combustible mantel leg clearances from side of unit as per diagram: Maximum 1-1/2" projection at 2" minimum clearance. Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
MANTEL CLEARANCES WITH VIGNETTE + VIGNETTE ONLY (No Vignette Finishing Trim) VIGNETTE FINISHING TRIM STEPPED FINISH MANTEL CLEARANCES WITH MANTEL CLEARANCES WITH VIGNETTE + VIGNETTE FINISHING TRIM SAFETY SCREEN AND LOUVERS FLUSH FINISH 12 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
6" (15cm) with AstroCap termination cap or is 6" (15cm) with AstroCap termination cap or 12" (30cm) with Rigid Vent termination cap. (For 12" (30cm) with Rigid Vent termination cap. (For example Dura-Vent). Example Dura-Vent). Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
6) Use steel studs for framing where the 1-1/2" (38mm) clearance from the vent to combustible material cannot be maintained. The HeatWave Duct Kit has different clearance and framing requirements, check the HeatWave manual for details. 14 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
11. Using the two (2) screws provided secure the cover plate to the Receiver. Low Voltage Junction Box Profl ame Receiver J-Box Receiver Slider Switch Wall Plate 10 ft. wire harness with 12 pin connector Diagram 1 Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
There are 5 vent systems approved for use with the P33-10: the Regency Direct Vent Flex System for Horizontal Terminations only and the Simpson Dura- ®...
* Clearance in accordance with local installation codes and the requirements of the gas supplier 3 feet (91cm) within a height of 15 feet (4.5m) above the meter / regulator assembly 3 feet (91cm) above - if within 10 feet (3m) horizontally Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
(Part# 946-523/P) Notes: spring 1) Liner sections should be continuous spacer without any joints or seams. 2) Only Flex pipe purchased from Regency ® 6-7/8" may be used for Flex installations. See Figure 1 below for (173mm) Alternate Caps.
INSTALLATION PROCEDURES for Regency Direct Vent System (Flex) ® 1) Locate the unit in the framing, rough in the *If this is an outside corner, the minimum distance between the vent and the outside gas (preferably on the right side of the unit) corner is 6"...
, Selkirk Direct-Temp. AstroCap is a proprietary trademark of FPI Fireplace ® Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc. 20 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
4DFSP 4DFS SV4BF TM-4CS Trim Plate-Black 4DT-TP 4DFPB 4DcP SV4LA TM-4TP Regency Fireplace Products . 6988 Venture St. . Delta, BC . Canada . V4G 1H4 . 604-946-5155 . www.regency-fi re.com Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
Page 22
Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard. Regency Fireplace Products . 6988 Venture St. . Delta, BC . Canada . V4G 1H4 . 604-946-5155 . www.regency-fi re.com...
Firestops are required at each floor level and whenever passing through a wall. • Maintain clearances to combustibles. Note: Must use optional rigid pipe adapter when using rigid vent systems (Part # 510-994). Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
Page 24
Propane and Natural Gas. Maximum two 45 elbows allowed. • Vent must be supported at offsets. • Firestops are required at each floor level and whenever passing through a wall. • Maintain clearances to combustibles. 24 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
Note: Must use optional rigid pipe adaptor (Part # 510-994) when using rigid pipe vent systems. (Refer "Rigid Pipe Venting Systems" Section) A vent guard should be used whenever the termination is lower than the specified minimum or as per local codes. Note: Regency Direct Vent System (Flex) ® is only approved for horizontal terminations.
Page 26
3' Max. 4' Min. 6' Max. Please note minimum 4' Max. 6' Min. 7' Max. 1 foot between 90 elbows is required. 5' Max. 8' Min. 8' Max. 26 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
Page 27
1 foot between 90 6' Max. 6' Min. elbows is required. 5' Min. 8' Max. 6' Min. For additional vertical venting with 2 x 90 elbows, refer to "Rigid Pipe Venting Arrangements" Section. Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
Page 28
5' Min. 6' Max. 8' Min. Please note min. 1 foot 6' Min. 7' Max. 9' Min. between 90 elbows is required. 7' Min. 8' Max. 10' Min. 28 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
VENTING ARRANGEMENTS - VERTICAL TERMINATIONS with Co-linear Flex System for both Residential & Manufactured Homes into Masonry Fireplaces Horizontal Distance (Feet) The shaded area in the diagrams show the allowable vertical terminations. 30 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
Failure to do so may result in pipe to the vent termination, slide the Wall drafting or performance issues not covered Thimble (Part # 620-926) over the vent under warranty. pipe. Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
Do not use open flame for leak testing. slide storm collar over the pipe section and Diagram 2 seal with a mastic. 32 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
2) Electronically Operated Hi/Lo 3) Pilot Adjustment 4) Thermocouple Connection - option 5) Outlet Pressure Tap 6) Inlet Pressure Tap 7) Pilot Outlet 8) Main Gas Outlet 9) Alternative TC Connection Point Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
Assembly to the left and lift out. label. 15. Check operation of flame control. 16. Check for proper flame appearance and glow on logs. Burner Orifice Reinstall new burner orifice LPG stamped #55 and tighten. Installer Notice: These instructions must be left with the appliance. 34 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ® 10.17.14 919-466...
5) Slide the Top Brick Panel into position and slide the Top Brick Retaining clips so that they hold the Top Brick Panel in place and tighten down the screws. 2nd Grate Tab Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
Note: Preferable if the thermostat is installed 16 GA. 32 Ft. on an interior wall. 18 GA. 20 Ft. Regency offers an optional programmable ® 20 GA. 12 Ft. thermostat but any 250-750 millivolt rated non- 22 GA.
CAUTION: Label all wires not touch any hot surfaces and are prior to disconnection away from sharp edges. when servicing controls. Wiring errors can cause improper and dangerous operation. 38 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
Unit will now operate using the wall thermostat. nector - see picture below. NOTE: When the remote receiver is set to ON position, the remote control transmitter and all of its features are now dis- abled. Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
THESE FANS COLLECT A LOT OF DUST FROM WITHIN YOUR HOME. ENSURE YOU MAINTAIN THESE FAN MOTORS ON A REGULAR BASIS BY VACUUMING THE FAN BLADES AND THE HOUSING WITH A SOFT BRUSH NOZZLE. 40 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ® 919-474 10.29.14...
Vignette frame (see below). Screen below. assembly is secured at bottom with magnets. Screen Assembly Vignette Frame Reverse Steps to remove. Secure Vignette frame using 2 screws in locations shown below. Final Install Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ® 12.03.14 919-468...
Hook Vignette Faceplate brackets into place. Line up the screw holes on the fi nishing trim and Vignette Face- plate bracket with the unit–fasten with one screw on each side– P33 only. 05.04.15 919-566 42 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
NOTE: Ensure Inlay is in correct position before pushing studs through the safety screen. Stud Nut + washer (supplied) Completed Install Line up Inlay–Push studs on Inlay through screen Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ® 05.21.15 919-559...
Line up the screw holes on the finishing trim and Vignette Faceplate bracket with the unit–fasten with one screw on each side. Reinstall the glass door and safety screen. Finishing Trim Top Finishing Trim Side 44 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ® 10.29.14 919-475...
4. Install bottom louver assembly by opening bottom louver enough to tighten screws. allow access to attach bottom louver brackets to unit with one screw on each side in locations shown below. Magnet locations 07.21.15 919-558a Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
Mettre le bouton de contrôle de gaz sur ''OFF'' pour éteindre la veilleuse. Pour économiser le carburant, éteindre la veilleuse quand l’appareil reste longtemps inutilisé. DO NOT REMOVE THIS INSTRUCTION PLATE 919-456 46 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
NEVER clean Button the glass while it is hot. Proflame video Diagram 2 Remote shown in Manual Mode on Hi 6. The unit will turn on. Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
NOT covered under warranty. Unit Body/Firebox: Note: Aeration Adjustment should only be Different types and thicknesses of steel will expand performed by an authorized Regency ® and contract at different rates resulting in some Installer at the time of installation or "cracking"...
(The DOOR GLASS pilot light generates enough heat to burn someone.) If for any reason a log should need replacement, you Your Regency fireplace is supplied with high ® must use the proper replacement log. The position...
Hint: If you are using black pipe, ensure that there is a union by the valve, otherwise removal will be almost impossible. screws Rear Log Stand Diagram 2: Rear Log Stand 50 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
Brick Panel - Top 430-056 Brick Clip - Top 430-057 Brick Clip - Bottom 438-917 Fan Assembly (120 Volts) Optional 910-331/P Fan Motor (120 Volts) 910-813 Power Cord (120 Volts) Part # Description Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
Pilot Tube w/nuts 910-073 DC spark box 910-074 DC spark box wire 911-030 Fan Control Module 439-969 Conversion Kit LP 911-032 Valve/Remote Wiring Harness 433-020 Pilot Shield *Not available as a replacement part. Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
Vignette Faceplate Tuscan Sunset 439-948 Vignette Door Inlay Black Chrome 439-949 Vignette Door Inlay Mt. Black 430-940 3 sided Finishing Trim 439-950 Vignette Door Inlay Tuscan Sunset Parts Not Shown 54 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
SAFETY SCREEN AND LOUVERS Part # Description 439-920 Flush louvers black 439-929 Safety Screen Regency Logo Plate 948-216 ® Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
Page 56
56 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
Page 57
Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
Page 58
58 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
Conditions: Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced at Regency's option, through an accredited distributor or agent provid- ed that the defective part be returned to the distributor or agent Transportation Prepaid, if requested.