LISTINGS AND CODE APPROVALS
These gas appliances have been tested in
accordance with AS4553-2000, NZS 5262
and have been certifi ed by the Australian
Gas Association for installation and opera-
tion as described in these Installation and
Operating Instructions.
Your unit should be serviced annually
by an authorised service person.
PG36 Gas Log Fireplace
PLEASE KEEP THESE INSTRUCTIONS
FOR FUTURE REFERENCE
WARNING:
Improper installation, adjustment, alteration,
service or maintenance can cause injury or
property damage. Refer to this manual. For
assistance or additional information consult
an authorised installer, service agency or the
gas supplier.
FOR YOUR SAFETY:
Do not store or use gasoline or other fl ammable
vapours and liquids in the vicinity of this or
any other appliance.
Installation and service must be performed by
an authorised installer, service agency or the
gas supplier.
918-545
Models: PG36NG3-R
PG36LPG3-R
FOR YOUR SAFETY:
What to do if you smell gas:
Do not try to light any
appliance
Do not touch any electrical
switch: do not use any phone
in your building.
Immediately call your gas
supplier from a neighbour's
phone. Follow the gas
supplier's instructions.
If you
cannot reach your
gas supplier, call the fi re
department.
05/26/06

Advertisement

Table of Contents
loading

Summary of Contents for Regency PG36NG3-R

  • Page 1 Owners & Installation PG36 Gas Log Fireplace Models: PG36NG3-R PG36LPG3-R PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING: FOR YOUR SAFETY: Improper installation, adjustment, alteration, What to do if you smell gas: service or maintenance can cause injury or Do not try to light any property damage.
  • Page 2: To The New Owner

    As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow. Please take a moment now to acquaint yourself with these instructions ® and the many features of your Regency Fireplace. ®...
  • Page 3: Table Of Contents

    Optional Brick Panels ..........22 Warranty ..............39 Log Set Installation ............22 Standard Flush Door ...........24 Wiring ................25 Remote Control ............26 Operating Instructions ..........26 Lighting Instructions ............26 Resetting The Unit ............26 Shutdown Instructions ..........26 First Fire ..............26 ® Regency PG36-3 Gas Log Fireplace...
  • Page 4: Data Badge

    DATA BADGE DATA BADGE NOTE: Regency ® units are This is a copy of the label that accompanies The label is located on the front inside base of the constantly being improved. Check the label on each PG36 Zero Clearance Room Sealed Gas unit, visible when the bottom louvre is open.
  • Page 5: Installation

    14) Under no circumstances should any solid fuels (wood, paper, cardboard, coal, etc.) be used in this appliance. 15) The appliance area must be kept clear and free of combustible materials, (gases and other fl ammable vapours and liquids). ® Regency PG36-3 Gas Log Fireplace...
  • Page 6: Clearances

    Have an Min. 6" authorized inspector, dealer, or installer (152mm) review your plans before installation. Note: For flue terminations see the "Exterior Flue Termination Locations" section. Clearances for Barcelona Front Diagram 1 ® Regency PG36-3 Gas Log Fireplace...
  • Page 7: Combustible Mantels

    INSTALLATION ® Regency PG36-3 Gas Log Fireplace...
  • Page 8: Mantel Leg Clearances

    6) Use steel studs for framing where the fl ue clearances in the "Locating Your Gas 1-1/2" (38mm) clearance from the fl ue to Fireplace" section. combustible material cannot be maintained, e.g. front top header. ® Regency PG36-3 Gas Log Fireplace...
  • Page 9: Unit Assembly Prior To Installation

    2) Use the same screw hole position for the Side Nailing Strips as was used for the Top Facing Support. Attach each side nailing strip using 3 screws. ® Regency PG36-3 Gas Log Fireplace...
  • Page 10: Exterior Flue Termination Locations

    (IV) A fl ue terminal of this type shall not be located under a roofed area unless the roofed area is fully open on at least two sides and a free fl ow of air at the appliance is achieved. ® Regency PG36-3 Gas Log Fireplace...
  • Page 11: Flueing

    Flex installations. ® 3) If you are installing the PG36 into a Regency Mantel Kit, use the minimum horizontal vent height (centre-line of 1029mm). Remember to include the mantel base in your calculations and to maintain the 32mm clearance (38mm with Flex) to the underside of the mantel top.
  • Page 12: Simpson Dura-Vent Flueing

    Vinyl Siding Shield for Riser Flue 903B 36" (914mm) Pipe Length - Black Snorkel - 14"(356mm) Rise Term.Cap Terminal 48" (1219mm) Pipe Length - Galv. Snorkel - 36" (914mm) Rise 902B 48" (1219mm) Pipe Length - Black Termination Cap ® Regency PG36-3 Gas Log Fireplace...
  • Page 13: Flueing Arrangements - Horizontal Terminations

    6-7/8" (175mm) outer diameter A fl ue guard should be used whenever the termination is lower than the specifi ed minimum or as per local codes. Note: Regency ® Co Axial Flue System (Flex) is only approved for horizontal terminations.
  • Page 14: Flueing Arrangements - Horizontal Terminations

    INSTALLATION FLUEING ARRANGEMENTS - HORIZONTAL TERMINATIONS SIMPSON DURA-VENT DIRECT FLUE GS SYSTEM and REGENCY ® CO AXIAL FLUE SYSTEM (FLEX) (LPG & NG) The diagram below shows examples of horizontal termination arrangements using two 90 elbows (two 45 elbows equal one 90 elbow).
  • Page 15: Flueing Arrangements - Vertical Terminations

    Maintain clearances to combustibles as listed in the "Clearances," "Locating Your Gas Fireplace," "Combustible Mantels," "Mantel Leg Clearances" & "Framing and Finishing" sections. Note: Must use optional fl ue adapter when using Simpson Dura-Vent pipe (Part # 510-994). Diagram 1 Diagram 2 ® Regency PG36-3 Gas Log Fireplace...
  • Page 16 Firestops are required at each fl oor level and whenever passing through a wall. • Maintain clearances to combustibles as listed in the "Clearances," "Locating Your Gas Fireplace," "Combustible Mantels," "Mantel Leg Clearances" & "Framing and Finishing" sections. Diagram 3 ® Regency PG36-3 Gas Log Fireplace...
  • Page 17: Horizontal Terminations

    fl ue pipe to the fl ue termination, slide the Note: Apply sealant "Mill-Pac" to inner Wall Thimble (Part # 620-926) over the fl ue pipe and high temperature silicone Diagram 5 pipe. sealant to outer pipe on every twist- lock joint. ® Regency PG36-3 Gas Log Fireplace...
  • Page 18: Vertical Terminations

    3.25 0.99 over 11/12 to 12/12 1.22 over 12/12 to 14/12 1.52 over 14/12 to 16/12 1.83 over 16/12 to 18/12 2.13 over 18/12 to 20/12 2.29 over 20/12 to 21/12 2.44 Diagram 3 ® Regency PG36-3 Gas Log Fireplace...
  • Page 19: Gas Connection

    Flue System: Simpson Dura-Vent Direct manual shut-off valve during any pressure ® Vent System or Regency Direct testing of the gas supply piping system at test Vent System (Flex) pressures equal to or less than 1/2 psig. (3.45 kPa).
  • Page 20: Conversion Kit For Ng To Lpg Model #516-969

    17) Replace the yellow "NG" label with the red "LPG" label. 18) Disconnect the 6 pin Molex connector and carefully pull out the control box. Rear Log Burner Tray NOTE: The control box is held in place with velcro. ® Regency PG36-3 Gas Log Fireplace...
  • Page 21 Put back the modulator plastic cap. WARNING: To ensure the correct operation of the modulator it is necessary that the plastic cap (A) is returned to its original location. ® Regency PG36-3 Gas Log Fireplace...
  • Page 22: Optional Brick Panels

    fi tting into the 2nd grate tab. 02-53 02-49 Vermiculite Vermiculite Vermiculite 3) Place the Log 02-49 on the rear log support 02-51 pins with the fl at side to the back. 2nd Grate Tab Cutouts ® Regency PG36-3 Gas Log Fireplace...
  • Page 23 02-49 02-50 02-52 02-53 02-51 02-54 Front Brackets Log indentation 02-55 02-52 02-50 02-53 Rear Grate 02-54 Photo shows rear grate tab. Notch Log 02-51 was removed to show the positioning of Log 02-52. ® Regency PG36-3 Gas Log Fireplace...
  • Page 24: Standard Flush Door

    Be careful that the glass gasket does not roll up; there must be a gap between the gasket and Note: Top and bottom louvres are the door lip to ensure that the door sits securely different. on the unit. Diagram 2. Diagram 2 ® Regency PG36-3 Gas Log Fireplace...
  • Page 25: Wiring

    This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from ® Regency PG36-3 Gas Log Fireplace...
  • Page 26: Remote Control

    REMOTE CONTROL FIRST FIRE LIGHTING INSTRUCTIONS ® Use the Regency Remote Control Kit approved The FIRST FIRE in your heater is part of the for this unit. Use of other systems may void paint curing process. To ensure that the paint 1) Plug the power cord into a power outlet.
  • Page 27: Operating Instructions

    Listed below are some examples. All are normal operating sounds and should not be considered NOTE: If you have an incorrect fl ame pattern, as defects in your appliance. contact your Regency ® dealer for further SUMMARY OF instructions.
  • Page 28: Copy Of The Lighting Plate Instructions

    Turn off all electric power to the unit if service is to be performed. DO NOT REMOVE THIS INSTRUCTION PLATE 918-332a WARNING: DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IN OPERATION. ® Regency PG36-3 Gas Log Fireplace...
  • Page 29: Maintenance

    NOT BE PLACED ON OR NEAR heat resistant paint (not with wall paint). THE APPLIANCE. Regency ® uses StoveBright Paint - Metallic 4) Inspect joints, to verify that no pipe Black #6309.
  • Page 30: Gold Or Brass Louvres & Trim

    # 936-243) and a tadpole glass gasket for the Flush Front (Part # 936-155). DOOR GLASS ® Your Regency fi replace is supplied with high temperature, 5 mm Neoceram ceramic glass that will withstand the highest heat that your unit will produce.
  • Page 31: Removing Valve Tray

    13) To replace the burner tray assembly reverse these instructions. 8) Remove the 10 Philips screws which secure the valve tray 14) Check for any gas leaks. assembly. 15) Check for proper fl ame appearance and glow on logs. ® Regency PG36-3 Gas Log Fireplace...
  • Page 32: Fan Replacement

    5) Unplug the 6 pin Molex connector and carefully pull out the ECS box. ECS Box 6 Pin Molex Connector 6) Remove the electric cover by undoing the 2 screws, pull out the grommet and the harness. Electric Cover ® Regency PG36-3 Gas Log Fireplace...
  • Page 33: Parts List

    910-912 Ignition Module to Valve Cable 910-906 Reset Switch 910-083 Ignition Module (1) 910-916 Ignition Module (2) 910-514 Jumper * Note: The Control Box Cable wires for the FG38 come separately: 910-502, 910-505, 910-506, 910-507, 910-509 ® Regency PG36-3 Gas Log Fireplace...
  • Page 34: Main Assembly

    Brick Panel Set - Herringbone Brown 513-904 Brick Panel Set - Herringbone Red 33) * Brick Panel - Back 34) * Brick Panel - Left 35) * Brick Panel - Right 511-031 Brick Clip (each) 918-545 Manual ® Regency PG36-3 Gas Log Fireplace...
  • Page 35: Burner Assembly & Log Set

    Middle Right Log 94) * Front Left Log 95) * Center Left Log 96) * Center Right Log 97) * Front Bottom Log 98) * Middle Left Log *Not available as a replacement part. ® Regency PG36-3 Gas Log Fireplace...
  • Page 36: Bay Front Assembly

    Bay Front Trim -Top/Bottom 120) * Flush Glass Retainer Bracket 780-934 Bay Door Trim - Gold *Not available as a replacement part. 113) * Bay Door Trim-Gold-Bottom 114) * Bay Door Trim-Gold-Top 112,114 112,113 ® Regency PG36-3 Gas Log Fireplace...
  • Page 37: Flush Front Accessories

    Finishing Trim (4 piece) - Steel 157) * Finishing Trim Left 158) * Finishing Trim Top 159) * Finishing Trim Right 160) * Finishing Trim Bottom 161) 513-949 Flush Door Screen Pkg. *Not available as a replacement part. ® Regency PG36-3 Gas Log Fireplace...
  • Page 38: Cast Faceplate Assembly

    202) * Cast Faceplate - Top 203) * Cast Faceplate - Left 513-996 Cast Grills (Set) - Black Enamel (Aust. only: 240 volt) 204) * Cast Grill - Top 205) * Cast Grill - Bottom ® Regency PG36-3 Gas Log Fireplace...
  • Page 39: Warranty

    The warranty does not extend to any part or parts which show evidence of misuse or abuse, neglect, accident, lack of maintenance, or improper installation. ® Products made by other manufacturers and used in conjunction with the operation of this appliance without authorization from Regency , may nullify your warranty on this product.
  • Page 40 Printed in Canada © Copyright 2006, FPI Fireplace Products International Ltd. All rights reserved.

This manual is also suitable for:

Pg36lpg3-r

Table of Contents