Appendix
For the United States and Canada
Use a UL listed and CSA labeled cord set consisting of a three conductor cord with a maximum length
of 15 feet. For units which stand on a desk or table, type SVT or SJT cord sets should be used.
For units which stand on the floor, only SJT type cord sets should be used.
The cord set must be selected according to the current rating for your unit.
Please consult the table below for the selection criteria for power cords used in the United States and
Canada.
table: Selection criteria for power cords used in the United States and Canada
Cord type
SJT
SVT
• Parallel
For units set at 115 V: Use a parallel blade, grounding
type
Attachment plug rated 15 A, 125 V.
For units set at 230 V (outside of the United States and Canada):
Use a cord set consisting of a minimum AWG according to the table above and a grounding type
attachment plug rated 15 A, 250 V. The cord set should have the appropriate safety approvals for the
country in which the equipment will be installed and should be marked HAR.
For the United Kingdom
Should the plug on the flexible cord not be of the type for your socket outlets, do not use an adapter but
remove the plug from the cord and discard. Carefully prepare the end of the supply cord and fit a suitable
plug.
The wires in this mains lead are colored in accordance with the following code:
• Green and Yellow: Earth
• Blue: Neutral
• Brown: Live
260
Size of conductors in cord
18 AWG
16 AWG
14 AWG
18 AWG
17 AWG
• This appliance must be earthed.
Maximum current rating of unit
10 Amps
12 Amps
12 Amps
10 Amps
12 Amps
• Tandem
For units set at 230 V: Use a tandem blade, grounding
type
Attachment plug rated 15 A, 250 V.