FireplaceXtrordinair Xtrordinair 44 Elite Installation Manual page 23

Wood-burning zero-clearance fireplace
Hide thumbs Also See for Xtrordinair 44 Elite:
Table of Contents

Advertisement

Facing Requirements (continued)
Facing may be installed so it inserts behind the faceplate (see Figure 28). . NOTE: the
faceplate protrudes 1" from the front of the fireplace, has a 1/8" overlap on the sides, and 1/4"
overlap on top.
The combustible area above the facing must not protrude more than 3/4" from the facing. If it
does, it is considered a mantel and must meet the mantel requirements listed in this manual.
To achieve a facing that is flush with the drywall to the side of the fireplace, recess the framing
directly next to the fireplace (see Figure 28).
TOP VIEW
(cross section of fireplace, framing, and face)
Fireplace
1-1/2"
1"
Flush Facing
Fireplace
© Travis Industries
Installation
Nail Down Flange
(used to secure the
fireplace to the framing)
1/2"
Faceplate
1/8" (1/4" overalap on
top, 0" on bottom)
Framing
1/2" Drywall
1/2" Concrete Board
3/8" Tile
(for qualified installers only)
Overlapped Facing
Fireplace
Brick Facing
Fireplace
4050714
Framing
1/2" Drywall
1/2" Concrete Board
3/8" Tile
Framing
1/2" Drywall
Brick
Figure 28
93508093
23