Facing Requirements - FireplaceXtrordinair Xtrordinair 44 Elite Installation Manual

Wood-burning zero-clearance fireplace
Hide thumbs Also See for Xtrordinair 44 Elite:
Table of Contents

Advertisement

22

Facing Requirements

NOTE: Artisan faces vary in size. If the facing is over 1" thick (brick, river-rock, etc.) use the
artisan face to create a template.
The fireplace is shipped with a set-up face that is 1/8" taller and wider than the finished
faceplate. This creates a 1/16" gap around the perimeter of the face when the finished face is
installed. Leave the set-up face in place to act as a template when installing the facing.
The fireplace requires 1/2" thick concrete-board or other non-combustible to extend from the
header to the base of the fireplace and to the framing members on both sides (do not use
sheetrock or drywall). See Figure 27.
The non-combustible facing must extend a minimum of 12" above and 2-1/2" to each side of
the faceplate.
The non-combustible facing must be a minimum 1" thick
Attach the cement board to the front of the fireplace with screws. Do not penetrate the
fireplace more than 3/4".
2-1/2"
(min.)
© Travis Industries
Installation
12" (min.)
(for qualified installers only)
Cement-board must
extend from the header
to the floor and to the
framing members on
both sides.
Non-combustible
Facing
Keep the set-up face
on the fireplace when
installing the facing.
4050714
Figure 27
93508093