Hearth Requirements

Local building codes may require a minimum hearth requirement different of what this manual
states
Hearth must extend 20" in front of the faceplate when it is not elevated (see local building
codes). Hearths raised 6-1/2" must extend a minimum 18".
Hearth must extend a minimum 8" to both sides of the faceplate (60" wide)
Hearth must be a minimum 1" thick of cement board (or equivalent)
Hearth must not rise more than 6-1/2" above the base of the fireplace
Minimum 1" cement board
Fireplace
Tile or
marble
Header height will
Ember
need to be increased
Strip
this dimension.
Fireplace
(Check Local Building Codes)
Ember
No hearth material can
Strip
go above this point
© Travis Industries
Installation
No combustible material
permitted above this point
2 x 4 Framing
15"
Raised
hearth
3/4"
Plywood
Faceplate
18" Min.
Combustible
Floor
(for qualified installers only)
Faceplate
Fireplace
Tile or
marble
Ember
Header height needs to be
Strip
increased this dimension.
Fireplace
6 1/2"
Max.
Ember
Strip
4050714
Elevated hearths must be
constructed of non-combustible
materials such as cement blocks
(6-1/2" Max.).
3/4"
Plywood
2 x 8 Framing
Faceplate
Combustible Floor
20" Min.
(Check Local Building Codes)
Min. 1" cement board
(or equivalent)
25
15"
Raised
hearth
Tile or
marble
Figure 30