Fireplace Placement Requirements; Minimum Framing Dimensions; Framing Dimensions At 45 - FireplaceXtrordinair Xtrordinair 44 Elite Installation Manual

Wood-burning zero-clearance fireplace
Hide thumbs Also See for Xtrordinair 44 Elite:
Table of Contents

Advertisement

10

Fireplace Placement Requirements

Minimum Framing Dimensions

The fireplace enclosure must not be
less than 81" above the base of the
fireplace.
• If the fireplace is raised, the
enclosure height must be raised to
maintain the 81".
• Do not build into this area.
• Do not slope the walls inward.
Framing Dimensions at 45°
© Travis Industries
Installation
50-1/2"
25"
25"
26"
72"
27"
(for qualified installers only)
26"
50"
Fireplace
(includes
1/2"
standoffs)
49"
4050714
A firestop is required at the top of
the fireplace enclosure or ceiling
level (whichever is lower).
Min. 4-1/2"
We recommend installing the
shaded framing members
after installing the chimney.
Arrange the framing
members so there is not a
vertical member directly in
the center of the opening
where it would interfere with
pipe clearances.
Header
(install veritcally to
ensure proper pipe to
header clearance)
NOTE: make sure the
enclosure is wide enough to
accommodate the blower
(see the section"Blower" for
details).
Figure 8
Figure 9
93508093