Abnormal Led Activity - Juniper ERX-1410 Installation And User Manual

Erx edge routers
Hide thumbs Also See for ERX-1410:
Table of Contents

Advertisement

8-8
CHAPTER 8
Troubleshooting

Abnormal LED Activity

Table 8-4 Troubleshooting abnormal LED activity on modules
Diagnostic Signs
POWER A OK is not lit
POWER B OK is not lit
FAIL LED lights
FAN OK does not light
FAN FAIL LED lights
Table 8-3 Normal activity of functional status LEDS during booting
OK
FAIL
ONLINE
off
on
off
off
off
off
on
off
off
on
off
on
If the system detects an error during booting, the FAIL LED turns on.
Some failure conditions may cause the board not to boot. In this case, the
LEDs may all be off. The system should then reset the board.
If the operational software detects an error, the FAIL LED turns on.
Some errors may cause a board reset. Crash information can be displayed
from the console and is printed to the screen on the next reboot.
See
Table 8-4
to diagnose and correct problems.
Possible Problems
System is not receiving
power from Power A.
System is not receiving
power from Power B.
The line module and I/O
module are incompatible.
A hardware failure, such
as a failed module.
Fan is not working
properly or has slowed
down.
Fan needs replacement.
Status Process
1 Module is in the power-up restart state; the FAIL
LED stays on briefly.
2 Module is initializing, and diagnostic tests are
running.
3 Module passed the diagnostics; the system boots.
4 Module is now up and running.
Actions
1 Check Power A and Power B terminal connections.
2 Verify that power switches are on.
3 Check connections to power sources.
4 If system still does not operate, contact Juniper
Networks Customer Service.
1 Check that the line and I/O modules are compatible;
replace if necessary.
2 If you replaced the I/O module only, issue the reload
slot slot_number command.
3 If you replaced the line module or if there was a
hardware failure, the system should automatically
reset the module.
4 If condition persists, contact Juniper Networks
Customer Service.
Contact Juniper Networks Customer Service; the system
must be serviced.