Fans; The Next Step - Juniper ERX-1410 Installation And User Manual

Erx edge routers
Hide thumbs Also See for ERX-1410:
Table of Contents

Advertisement

The Next Step

1-15
ERX Edge Routers

Fans

Forced air-cooling keeps the temperature of the ERX modules and
components within normal operating limits. In the ERX-1400 series, six
cooling fans are located in a tray at the top of the system (see
Figure
7-5).
In the ERX-700 series, four cooling fans are located in a tray on one side
of the system (see
Figure
7-7).
The system monitors the temperature of each module. If the temperature
of a module exceeds the maximum limit, the system immediately goes
into thermal protection mode. In this mode, the modules consume
extremely low levels of power. For information about troubleshooting
high operating temperatures, see
Chapter 8,
Troubleshooting.
The fan tray has two redundant converters that power the fans (for the
ERX-1400 series, a –24 V, 50 W converter; for the ERX-700 series, a
–12 V, 15 W converter). If one converter fails, the other takes over. In
addition, the system software reports an alarm if any of the fans
overrotate or underrotate or if one of the converters fails.

The Next Step

Go to
Chapter 2, Installing the ERX
System.

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Erx-1440Erx-700Erx-705

Table of Contents