Table B-3 Connection information for module assemblies
Assembly
Line
Name and
Module
Capability
Label
CE1
CE1
cOC3/STM1
cOCx/STMx
multimode
F0
cOC3/STM1
cOCx/STMx
single mode
F0
intermediate
reach
Table B-3
shows the names of the line modules and I/O modules that you
can combine to form the different module assemblies. This table also
provides cabling specifications for the I/O modules.
I/O Module
No. of
Label
Ports
CE1
20
FULL
I/O
cOC3
4
STM1
F0 I/O
MULTI
MODE
cOC3
4
STM1
F0 I/O
SINGLE
MODE
Connector Type
Cabling Specifications
RJ-48C,120 ohm
BNC, 75 ohm
via a balun panel
that connects to
the I/O module
SC full duplex
SC full duplex
Connection Information
ERX Edge Routers
Use shielded cables to
maintain EMC compliance.
The transmitted signal
complies with
ITUT G.703:
Physical/electrical
characteristics of hierarchical
digital interfaces (November
2001)
for cable lengths up to
450 m (492 yards).
Tx power:
min: –19 dBm
max: –14 dBm
Center wavelength: 1310 nm
Rx input power:
min: –30 dBm
max: –14 dBm
Rated for 2 km (1.2 miles)
over 62.5-micron core cable
with an optical loss of 0–9 dB
or 50-micron core cable with
an optical loss of 7 dB
Tx power:
min: –15 dBm
max: –8 dBm
Center wavelength: 1310 nm
Rx input power:
min: –31 dBm
max: –8 dBm
Rated for 15 km (9.3 miles) of
9-micron core cable
B-7