Checking And Adjusting The Air Pressure; Cleaning The Filter Of The Air Filter/Regulator - Pfaff 3566-2/02 Instruction Manual

Table of Contents

Advertisement

Care and maintenance
12

Checking and adjusting the air pressure

.04
Fig. 12 - 04
12

Cleaning the filter of the air filter/regulator

.05
12 - 4
8
10
6
100
150
4
50
200
2
230
0
0
1
8
10
6
100
150
4
50
200
2
230
0
0
2
1
Fig. 12 - 05
2
12
14
16
Emptying water bowl 1:
12
14
16
Cleaning filter 2:
Check the air pressure on gauge 1 every
time before operation.
Gauge 1 must show a pressure of 6 bar.
If necessary, adjust to this setting.
To do so, lift knob 2 and turn it until the
guage shows a pressure of 6 bar.
Switch the machine off!
Disconnect the air hose at the
air filter/regulator unit.
Water bowl 1 empties itself automatically
when the air hose is disconnected from
the air filter/regulator.
Unscrew water bowl 1.
Take out filter 2.
Clean filter 2 with compressed air or
isopropyl alcohol
(part No. 95-665 735-91).
Screw in filter 2 and screw on water
bowl 1.