Care and maintenance
12

Checking/adjusting the air pressure

.05
12
Cleaning the air fi lter of the air-fi lter/lubricator
.06
86
1
0.4
0.6
0.2
0.8
0
1
+
-
3
Fig. 12 - 06
0.4
0.6
0.2
0.8
0
1
+
-
2
1
Fig. 12 - 07
● Before operating the machine, always
2
● Gauge 1 must show a pressure of 6 bar.
● If necessary adjust to this reading.
● To do so, pull knob 2 upwards and turn
Confi guration of the pressure controller:
● Turn screw 3 until the green arrow points
134-010
Bar
4,5
= 0,45
5
= 0,5
6
= 0,6
To drain water bowl 1:
● Water bowl 1 drains itself automatically
Cleaning fi lter 2:
● Unscrew water bowl 1.
● Take out fi lter 2.
● Clean fi lter 2 with compressed air or iso-
● Screw in fi lter 2 and screw on water
134-011
check the air pressure on gauge1.
it so that the gauge shows a pressure of
6 bar.
to 4.5 bar.
The machine is automatically switched
off if a pressure of < 4.5 bar is reached,
and can be automatically reactivated,
once pressure reaches a value > 5.0 bar.
MPa
Switch the machine off!
Disconnect the air hose at the
air-fi lter/lubricator.
when the compressed-air hose is discon-
nected from the air-fi lter/lubricator.
propyl alcohol (part No. 95-665 735-91).
bowl 1.
psi
= 65
= 73
= 87