Pfaff 3566-2/02 Instruction Manual page 38

Table of Contents

Advertisement

Programming
10 - 9
6 - SWITCHING OF INPUTS
In this function, after the code number is selected and verified with the enter key, the
corresponding output can be selected with number key 1 and reset with
number key 0.
Code number Terminal
8
1
9
2
10
3
11
4
12
5
13
6
14
7
15
8
16
9
17
10
18
11
19
12
20
13
21
14
22
15
23
16
0
17
1
18
2
19
3
20
4
21
5
22
6
23
7
24
24
5
7 - SOFTWARE DATE
When this function is enabled, the date of the control software (CPU) is indicated.
Output board
Output
A25
Y1.1
Y12
Y1.2
Y1
Y2
Y3
Y4
Y5
Y6
K7
-
-
Y10
Y11
Y13
-
-
Y15
L14.1
L14.2
L14.3
L14.4
-
Y7
BOBRES
REF
Y4
Function
Guide blade back
Guide blade pressure (only
with feed table)
Guide blade forward
Guide blade forward (only
with feed table)
Guide blade right
Work holder up
Airblast on
Thread trapper on
Thread trapper up
Thread trim on
(only on PFAFF 3566-2/02)
free
free
Thread tension release on
Small-part stop back
Brake for engaging depth
(only with feed table)
free
free
Suction on (only with feed table)
Stepping motor, engaging depth, coil 1
Stepping motor, engaging depth, coil 2
Stepping motor, engaging depth, coil 3
Stepping motor, engaging depth, coil 4
free
Bobbin-thread monitor reset
(only on PFAFF 3566-3/02)
Reset für Unterfadenwächter
Reference output for needle in
material
Special commands:
Airblast function (timed reset)