Checking / Adjusting The Air Pressure; Emptying/Cleaning The Water Container Of The Air Filter/Regulator - Pfaff 294 Instruction Manual

Hide thumbs Also See for 294:
Table of Contents

Advertisement

10
Checking and adjusting the air pressure
.06
1
Fig. 10 - 05
10

Emptying/cleaning the water container of the air filter/regulator

.07
1
Fig. 10 - 06
2
max.
2
Care and maintenance
Before each use of the machine, check
the air pressure on gauge 1.
The gauge 1 must display a pressure of
6 bar.
If necessary, alter the pressure to this
level. To do so, lift knob 2 and turn it until
the required pressure is reached.
Turn the machine off.
Remove the compressed air hose
from the air filter.
Emptying the water container
The water container 1 1 1 1 1 empties itself
automatically when the compressed-air
hose is removed from the air filter/
regulator.
Cleaning the filter
Unscrew water container 1 and remove
filter 2.
Clean the filter with compressed air or
with isopropyl alcohol, part number
95-665 735-91.
Screw filter 2 back into place and screw
water container 1 back on.