4. System exclusive messages
4.1 Parameter changes
This unit transmits and receives the following 13 types of parameter
change. (However, 13.Remote Switch is only received.) For 13.Remote
Switch, the screen will be the same as when the switch is pressed.
Parameter change format is as follows.
Format for 1) — 3)
For details of ggggg, hh, ppppppp, ddddddd, see the following items.
For the format of 4)... see 4.1.4.
For the format of 5)... see 4.1.5.
For the format of 6)... see 4.1.6.
For the format of 7)... see 4.1.7.
For the format of 8)... see 4.1.8.
For the format of 9)-12)... see 4.1.9.
For the format of 13)... see 4.1.10.
4.1.1 VCED parameter change
VCED (Voice edit buffer) messages change data one parameter at a
time. For ppppppp (parameter number) and ddddddd (data), see table
1.
Single mode is automatically entered when this message is received.
4.1.2 ACED / ACED2 / ACED3 parameter change
ACED/ACED2 (Additional voice edit buffer) messages change data
one parameter at a time. For ppppppp (parameter number) and
ddddddd (data), see table 1.
Single mode is automatically entered when this message is received.
4.1.3 PCED parameter change
PCED (Performance edit buffer) messages change data one parameter
at a time. For ppppppp (parameter number) and ddddddd (data), see
table 1.
Performance mode is automatically entered when this message is re-
ceived.
4.1.4 PCED2 parameter change
Format
PCED2 messages change data one parameter at a time. For kkkkkkk
(parameter number) and ddddddd (data), see table 1.
Performance mode is automatically entered when this message is re-
ceived.
4.1.5 System parameter change (SYS, SYS2, SYS3)
Format
These messages change system data one parameter at a time.
For kkkkkkk (parameter number) and ddddddd (data), see table 3.
4.1.6 Effect parameter change
Format
These messages change PFM Effect (delay, pan, chord) data one pa-
rameter at a time. The value of ppppppp sets the group number.
For kkkkkkk (parameter number) and ddddddd (data), see table 3.
4.1.7 Micro tuning parameter change
Format
These messages change micro tuning data one key at a time.
For kkkkkkk (key number) and ddddddd (data), see table 3.
4.1.8 Program change parameter change
Format
These messages change the PGM Change Table data. Data has the
following meaning.
For kkkkkkk (PGM change number), see table 3.
131