Four Slot Spare Battery Charger
Troubleshooting the Four Slot Spare Battery Cradle
Table 15-7
Symptom
Charge LEDs do not
Cradle is not receiving power.
light when batteries
are inserted.
Battery is not seated correctly in
the cradle.
Extreme battery temperature.
Battery is not
Battery was removed from cradle
charging.
or cradle was unplugged from
AC power too soon.
Battery is faulty.
Battery is not fully seated in the
cradle.
Extreme battery temperature.
Possible Cause
Maintenance and Troubleshooting 15 - 13
Ensure the power cable is connected securely to both the
cradle and to AC power.
Remove and re-insert the battery, ensuring it is correctly seated.
Battery does not charge if battery temperature is below 32°F
(0°C) or above 104°F (40°C).
Ensure cradle is receiving power. Ensure battery is seated
correctly. If a battery is fully depleted, it can take up to four
hours to fully recharge the Li-ion battery.
Verify that other batteries charge properly. If so, replace the
faulty battery.
Remove and re-insert the battery into the cradle, ensuring it is
correctly seated.
Battery does not charge if battery temperature is below 32°F
(0°C) or above 104°F (40°C).
Action