External Trigger Programmable Exposure

Also known as "Edge Pre-select" exposure. See the timing diagram below.
The external trigger edge initiates the exposure process. The active external trigger edge can be selected as
either the low-high or high-low transition.
The delay from active trigger edge to start of exposure is programmable from 1μs to 4 seconds (1μs steps) .
Exposure duration is programmable from 100μs to 4 seconds (1μs steps).
Supports "Synchronous
on the next horizontal line while exposure duration granularity is 1µs. Exposure and sensor readout can be
concurrent.
Supports "Reset
Mode" on page 49
sequential, limiting the maximal frame rate.
Any external trigger received before the previous exposure is complete is ignored. An application can elect to
receive messages about ignored triggers. See
Genie Monochrome Series-GigE Vision Camera
Mode" on page 48
timing for fastest possible frame rates. Start of exposure is aligned
timing. Exposure granularity is 1µs. Exposure and sensor readout must be
"Events" on page
Programmable Synchronous Mode Exposure Timing
Programmable Reset Mode Exposure Timing
65.