Status LED Codes

The camera is equipped with a LED to display the operational status of the camera. When more than one condition
is active, the LED color indicates the condition with the highest priority (such as an acquisition in progress has more
priority than a valid IP address assignment). The following table summarizes the LED states and corresponding
camera status.
LED State
LED is off
Steady Red
Slow Flashing Red
Fast Flashing Red
Slow Flashing Blue
Fast Flashing Blue
Steady Blue
Steady Green
Slow Flashing Green
Fast Flashing Green
Once the Genie has its RJ45 connected to a network, the Status LED will turn to steady blue when the IP address is
assigned. Only at this time will it be possible by the GigE Server or any application to communicate with the
camera.
Note: Even if the Genie has obtained an IP address, it might be on a different subnet than the NIC it is attached to.
Therefore, if the Genie LED is blue but an application such as CamExpert can not see it, this indicates a network
configuration problem.
22 • Installing the Genie Camera
Definition
No power to the camera
Camera not initialized
Camera initialization problem
Camera is too hot
Waiting for an IP address
Ethernet cable disconnected (no link)
IP address assigned;
no application connected to the camera
Application connected
Triggered acquisition in progress
Free-running acquisition in progress