Appendix 5: Digital Interface
DBT - Depth below transducer
Recipient of sentences:
Expected nominal interval of sentences: 5 s
Alarm generated if message not received: 22 s ± 2 s
$--DBT,x.x,f,x.x,M,x.x,F*hh<CR><LF>
| | |
|
| | |
| | |
|
| | +--------- 4
| | |
| +--+----------- 3
| | +--+----------------- 2
+--+---------------------- 1
1. Water depth, feet
2. Water depth, m
3. Water depth, fathoms
4. Checksum
DPT - Depth
Recipient of sentences:
Expected nominal interval of sentences: 5 s
Alarm generated if message not received: 22 s ± 2 s
$--DPT,x.x,x.x,x.x*hh<CR><LF>
|
|
|
|
|
|
| +----- 4
|
|
+--------- 3
|
+------------ 2
+---------------- 1
1. Water depth relative to trancsducer, in meters
2. Offset from transeducer, in meters (see notes 1 and 2)
3. Maximum range scale in use
4. Checksum
NOTE1 "positive"=distance from transeduser to water-line.
"-"=distance from transducer to keel.
NOTE2 For IEC applications the offset should always be applied
so as to provide depth relative to the keel.