Semi-Annual Checks And Services - Frymaster FM45E Installation & Operation Manual

45 series gas fryers
Table of Contents

Advertisement

5. Remove the thermometer or pyrometer.
If calibration cannot be obtained for any rea-
son, call a Factory Authorized Service Center
for assistance.
Check Thermostat Controller Thermostat
Calibration
(This check applies only to units equipped
with Thermostat Controllers)
1. Set the temperature control knob to 325° F
(162° C) and insert a good grade ther-
mometer or pyrometer into the frypot so
that it touches the temperature probe
guard.
2. When the burner cycles off, set the tem-
perature control knob to 340° F (170° C).
As the reading on the thermometer or py-
rometer nears the control knob setting, but
before the burner cycles off, reset the knob
to 325° F (162° C). Just as the reading on
the thermometer or pyrometer drops below
325° F (162° C), the burner should cycle
on. If it does not, calibration is required.
Call your Factory Authorized Service
Center (FASC) to arrange this service.
Check Computer Magic III Set Point
Accuracy
(This check applies only to units equipped
with Computer Magic III Controllers.)
1. Insert a good-grade thermometer or
pyrometer into the oil/shortening, with the
end touching the fryer temperature sensing
probe.
2. When the computer display shows a series
----
of four dashes (
45 SERIES GAS FRYERS
CHAPTER 5: PREVENTIVE MAINTENANCE
) with no red dot
between the first and second dashes (indi-
cating that the frypot contents are within
the cooking range), press the
once to display the temperature of the
cooking oil or shortening as sensed by the
temperature probe.
3. Press the
switch twice to display the set
point.
4. Note the temperature on the thermometer
or pyrometer. All three readings should be
within ± 5ºF (2ºC) of each other. If not,
contact a Factory Authorized Service
Center for assistance.
Clean Gas Valve Vent Tube
1. Carefully unscrew the vent tube from the
gas valve. NOTE: The vent tube may be
straightened for ease in removal.
2. Pass a piece of ordinary binding wire (.052
inch diameter) through the tube to remove
any obstruction.
3. Remove the wire and blow through the
tube to ensure it is clear.
4. Reinstall tube and bend it so that the
opening is pointing downward.
SEMI-ANNUAL CHECKS AND
SERVICES
Check Burner Manifold Pressure
This task should be performed by
qualified service personnel only.
1. Ensure that the gas valve knob is in the
OFF position.
5-4
switch
WARNING