General Checkout - IBM IntelliStation M Pro 6233 Hardware Maintenance Manual

Type 6233 and 6850
Table of Contents

Advertisement

General checkout

This general checkout procedure is for Types 6233 and 6850 computers.
Diagnostic error messages appear when a test program finds a problem with a
hardware option. For the test programs to properly determine if a test Passed,
Failed or Aborted, the test programs check the error-return code at test completion.
See "Diagnostics" on page 18.
General error messages appear if a problem or conflict is found by an application
program, the operating system, or both. For an explanation of these messages,
refer to the information supplied with that software package.
Notes:
v Types 6233 and 6850 computers default to come up quiet (no beep and no memory count and checkpoint code
display) when no errors are detected by POST.
v To enable beep and memory count and checkpoint code display when a successful POST occurs, do the following:
1. Select Start Options in the Configuration/Setup Utility program (see "Setup Utility program" on page 17).
2.
Set Power-On Self-Test to Enhanced.
v Before replacing any FRUs, ensure that the latest level of BIOS is installed on the system. A down-level BIOS
might cause false errors and unnecessary replacement of the system board. For more information on how to
determine and obtain the latest level BIOS, see "BIOS levels" on page 39.
v If multiple error codes are displayed, diagnose the first error code displayed.
v If the computer hangs with a POST error, go to "POST error codes" on page 91.
v If the computer hangs and no error is displayed, go to "Undetermined problems" on page 96.
v If an installed device is not recognized by the diagnostics program, that device might be defective.
1. Power-off the computer and all external devices.
2. Check all cables and power cords.
3. Make sure the system board is seated properly.
4. Set all display controls to the middle position.
5. Power-on all external devices.
6. Power-on the computer.
7.
DID YOU RECEIVE THE CORRECT RESPONSE?
NO, continue to 002 .
YES, proceed to 003 .
© Copyright IBM Corp. 2002
Attention:
The drives in the computer you are servicing might have been rearranged or the drive
startup sequence changed. Be extremely careful during write operations such as copying,
saving or formatting. Data or programs can be overwritten if you select an incorrect drive.
001
Check for the following response:
v Readable instructions or the Main Menu.
1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Intellistation m pro 6850Intellistation m pro

Table of Contents