Post Error Codes - IBM IntelliStation M Pro 6233 Hardware Maintenance Manual

Type 6233 and 6850
Table of Contents

Advertisement

POST error codes

In the following error codes, X can be any number or letter.
Error Code/Symptom
062
(Three consecutive boot
failures using the default
configuration.)
101, 102, 106
(System and microprocessor
error)
111
(Channel check error)
114
(Adapter read-only memory
error)
129
(Internal cache error)
151
(Real time clock error)
161
(Real time clock battery error)
162
(Device Configuration Error)
Note: Be sure to load the
default settings and any
additional desired settings;
then, save the
configuration.
163
(Real-Time Clock error)
164
(Memory configuration
changed)
175
(Hardware error)
176, 177, 178
(Security hardware error)
FRU/Action
1. Run Configuration/Setup
2. Battery
3. System Board
4. Microprocessor
1. System Board
1. Failing adapter
2. DIMM
3. System board
1. Failing adapter
2. Run diagnostics
1. Microprocessor
1. Run Diagnostics
2. Battery
3. System Board
1. Run Configuration/Setup
2. Battery
3. System Board
1. Run Configuration/Setup
2. Battery
3. Failing Device
4. System Board
1. Run Configuration/Setup
2. Battery
3. System Board
1. Run Configuration/Setup
2. DIMM
3. System Board
1. System Board
1. Run Configuration/Setup
2. System Board
91