Setting Record - Biasi Advance Plus 25C User Manual And Installation Instructions

Biasi advance plus wall hung, fanflue, roomsealed, high efficiency gas boiler
Hide thumbs Also See for Advance Plus 25C:
Table of Contents

Advertisement

Fig. 7.43
• Scroll the various parameters using keys
15 or 16 until the letters Pr that alternate
with code 12 are displayed on the LCD
display, indicating that "parameter 12"
(Fig. 7.44) has been activated.
Fig. 7.44
• Press keys 14 and 16 (Fig. 7.42) at the
same time until the value of parameter 12
(74=Advance Plus 25C or 78=Advance
Plus 30C or 84=Advance Plus 35C) is dis-
played on the LCD display (Fig. 7.45).
COMMISSIONING
Fig. 7.45
• It is possible to modify parameter using
keys 15 or 16 (Fig. 7.42) (Refer to Fig.
7.41 and determine the correct Value ap-
pertaining to the output required for the
central heating requirement.).
• By pressing key 14 (Fig. 7.42) confirma-
tion of the inserted value is obtained.
• Press keys 14 and 15 (Fig. 7.42) at the
same time to exit without changing the
value (return to the parameters list Fig.
7.44)
• Press keys 14 - 15 - 16 (Fig. 7.42) at the
same time for 10 seconds to exit the "pro-
gramming mode".

7.19 Setting record

Important: at the end of the setting op-
eration it is important to fill/update the
table (Fig. 7.46).
This to allow a correct setting of this
boiler in case of replacement of the main
control p.c.b.
PARAMETER
Boiler type (to be
updated with the
complete range)
Not used
Pump speed
Not used
Gas type
DIGIT
VALUES
Pr 01
Pr 02
---------------
Pr 03
Pr 04
---------------
Pr 05
- 69 -