Detailed Control Command List Of The Ar-Alpha; Power On - AOR AR-ALPHA Operating Manual

Digital processing communications receiver
Hide thumbs Also See for AR-ALPHA:
Table of Contents

Advertisement

9-3 Detailed control command listings for the AR-ALPHA
^A AC AF AG
Remote power on
Remote ON
^Ann
AGC
AC
ACn (n: 0 ~ 3)
To read: AC <CR>
Response:
ACn
AFC
AF
AFn
To read: AF <CR>
Response:
AFn
AF gain
AG
AGnnn
To read: AG <CR>
Response:
AGn
AN AQ AS AT
Antenna input
ANn (n: 1 ~ 4)
AN
n = 1 Antenna input 1
n = 2 Antenna input 2
n = 3 Antenna input 3
n = 4 Antenna input 4
To read: AN <CR>
Response:
ANn
Hex value 0x01
Accept a value nn in the range of 00-99 for remote
connection
n = 0 (AGC Fast)
n = 1 (AGC Middle)
n = 2 (AGC Slow)
n = 3 (Manual gain control)
n = 0 (AFC off)
n = 1 (AFC on)
n = 0 ~ 255 (n: 0 = mute, no audio)
(An optional antenna relay is required.)
(An optional antenna relay is required.)