Chapter 10 The Service Configuration Screens
The following table describes the labels in this screen.
Table 36 VOICE > Service Configuration > SIP Setting
LABEL
SIP Account
SIP Settings
Active SIP
Account
Number
SIP Local
Port
SIP Server
Address
SIP Server
Port
REGISTER
Server
Address
REGISTER
Server Port
SIP Service
Domain
Send Caller ID
Authentication
User Name
Password
Apply
Reset
Advanced
114
DESCRIPTION
Select the SIP account you want to see in this screen. If you change this
field, the screen automatically refreshes.
Select this if you want the WiMAX Modem to use this account. Clear it if
you do not want the WiMAX Modem to use this account.
Enter your SIP number. In the full SIP URI, this is the part before the @
symbol. You can use up to 127 printable ASCII characters.
Enter the WiMAX Modem's listening port number, if your VoIP service
provider gave you one. Otherwise, keep the default value.
Enter the IP address or domain name of the SIP server provided by
your VoIP service provider. You can use up to 95 printable ASCII
characters. It does not matter whether the SIP server is a proxy,
redirect or register server.
Enter the SIP server's listening port number, if your VoIP service
provider gave you one. Otherwise, keep the default value.
Enter the IP address or domain name of the SIP register server, if your
VoIP service provider gave you one. Otherwise, enter the same address
you entered in the SIP Server Address field. You can use up to 95
printable ASCII characters.
Enter the SIP register server's listening port number, if your VoIP
service provider gave you one. Otherwise, enter the same port number
you entered in the SIP Server Port field.
Enter the SIP service domain name. In the full SIP URI, this is the part
after the @ symbol. You can use up to 127 printable ASCII Extended
set characters.
Select this if you want to send identification when you make VoIP phone
calls. Clear this if you do not want to send identification.
Enter the user name for registering this SIP account, exactly as it was
given to you. You can use up to 95 printable ASCII characters.
Enter the user name for registering this SIP account, exactly as it was
given to you. You can use up to 95 printable ASCII Extended set
characters.
Click to save your changes.
Click to restore your previously saved settings.
Click this to edit the advanced settings for this SIP account. The