Crs-180 Switch Dip Settings; Table 3-1. Crs-180 Dip Switch Settings; Figure 3-3. Crs-180 Antenna Side - Dip Switches - Comtech EF Data CRS-180 Installation And Operation Manual

70/140 mhz if 1:1 redundancy switch
Hide thumbs Also See for CRS-180:
Table of Contents

Advertisement

CRS-180 70/140 MHz IF 1:1 Redundancy Switch
Modem and Switch Configuration
3.6

CRS-180 Switch DIP Settings

The  'Switch  Conditions'  DIP  switches  are  set  depending  upon  the  type  of  Tx  or  Rx 
traffic conditions resultant of switchover. Some modems have additional settings or 
alarm  masks  that  affect  conditions  –  refer  to  the  pertinent  modem  manual  for 
detailed explanations. 
 
Figure  3‐3  shows  the  DIP  switches  for  setting  'Switch  Conditions'  on  the  Antenna  Side  of  the 
CRS‐180 70/140 MHz IF 1:1 Redundancy Switch. Table 3‐1 illustrates the 'Switch Conditions' DIP 
switch settings that determine switchover functionality for a given redundancy configuration.  
 
DIP
Left Switch
Down (Off)
Down
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Table 3-1. CRS-180 DIP Switch Settings

'Switch Conditions' DIP Settings
Right Switch
Down
Up
Down
Up
Up
Up
Figure 3-3. CRS-180 Antenna Side – DIP Switches
Result
Switchover upon a Unit fault
Switchover upon a Unit or Tx Traffic fault
Switchover upon a Unit or Rx Traffic fault
Switchover upon a Unit or Tx Traffic or Rx Traffic fault
3–13
Revision 8
MN/CRS180.IOM