10/100 Ethernet Interface Example - Comtech EF Data CRS-180 Installation And Operation Manual

70/140 mhz if 1:1 redundancy switch
Hide thumbs Also See for CRS-180:
Table of Contents

Advertisement

CRS-180 70/140 MHz IF 1:1 Redundancy Switch
Cables and Connections
4.4.4.4

10/100 Ethernet Interface Example

Figure 4‐26 shows a block diagram and cabling example of a CDM‐570 1:1 modem configuration 
using the 10/100 Ethernet Interface. User‐provided Ethernet cables are connected directly to the 
ports, so no cables or kit is required.  
 
For the CDM‐570 in Managed Switch (Ethernet Bridge) Mode, the user MUST use an 
external  Ethernet  hub  to  insure  that  traffic  will  continue  after  a  switchover.  If  an 
Ethernet  switch  is  used,  there  could  be  a  several  minute  outage  while  the  Ethernet 
Switch  "re‐learns"  the  correct  output  Ethernet  port.  Using  a  "dumb"  Ethernet  hub 
allows  LAN  to  WAN  traffic  to  continue  even  after  a  switchover  occurs  since  both 
modems will be receiving the LAN traffic.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
CDM-570 Block Diagram: 10/100 Ethernet Interface
Figure 4-26. CDM-570 10/100 Ethernet 1:1 Example
4–27
Revision 8
MN/CRS180.IOM

Advertisement

Table of Contents
loading

Table of Contents