Modem-To-User Data Interface Kit And Connection Examples - Comtech EF Data CRS-180 Installation And Operation Manual

70/140 mhz if 1:1 redundancy switch
Hide thumbs Also See for CRS-180:
Table of Contents

Advertisement

CRS-180 70/140 MHz IF 1:1 Redundancy Switch
Cables and Connections
4.7.2

Modem-to-User Data Interface Kit and Connection Examples

In  addition  to  the  basic  switch‐to‐modem  cabling  shown  in  the  previous  section,  a  number  of 
data interface configuration kits are available for use with the CDM‐710G. 
 
 
 
 
 
 
Figure 4-39. CDM-710G Block Diagram: User
 
Figure  4‐39  shows  a  block  diagram  typical  for  the  kits  shown  in  Sects.  4.7.2.1  and  Sect.  4.7.2.2. 
Separate cabling kits are needed for these CDM‐710G data interfaces. For example, Sect. 4.7.2.1 
identifies the interface kit used for the CDI‐10‐1 Single G.703 Data Interface. With the exception of 
the CDI‐70 Gigabit Ethernet Data Interface configuration shown in Sect. 4.7.2.3, where user‐provided 
Ethernet cables and Layer 2 Switch are used, one interface kit per 1:1 modem pair is required for 
each interface (see examples for specified quantities). 
 
The data interface combinations allowable in Interface Slots 1 and 2 of the CDM‐710G chassis are 
as follows: 
 
Allowable CDM-710G Combinations
Interface Slot 1
Single G.703 (CDI-10-1)
HSSI (CDI-60)
None
 
Interface Slot 2
None
None
GigE (CDI-70)
4–45
MN/CRS180.IOM
Modem
Switch
Revision 8
Traffic

Advertisement

Table of Contents
loading

Table of Contents