CRS-180 70/140 MHz IF 1:1 Redundancy Switch
Cables and Connections
4.6.2.1
ASI 75Ω Data Interface (CDI-40) Kit KT/12579
Figure 4‐35 shows an example of a CDM‐710 1:1 modem configuration with the CDI‐40 ASI Data 
Interface installed in Slot 1, and Slot 2 empty. The figure depicts installation of one KT/12579 ASI 
Interface Kit. 
 
Be sure to connect to the lower BNC connectors labeled "1:1" on the CDI-40 ASI Data Interface. The
Rx port on each interface has been tuned to be 3 dB higher amplitude to compensate for the
presence of the RF/SA32KC-IN/OUT 2-way combiner.
 
 
CEFD Part No.
CA/BNC75OHM
RF/SA32KC-IN/OUT
 
KT/12579 ASI (CDI-40) 75Ω Interface Kit
Qty
Description
4
Cable – IF BNC, 75Ω, 1'
2
Combiner – 2-way w/Bracket, 0.25-300 MHz, 75Ω BNC
Figure 4-35. CDM-710 ASI 1:1 Example