Aastra DT4x3 DECT Telephones
6

Alarm Operation

The parameters described in this chapter are set in the PDM/Device Manager. See the
handset's Configuration Manual.
Note: The alarm functionality is applicable for DT423/DT433 only.
6.1

Push-Button Alarm

The push-button
press. By default, long press is defined for test alarm (see
press is defined for personal alarm (see
6.1.1

Test Alarm

Press and hold the push-button
following occurs;
• a beep is heard
• the orange LED flashes twice
• the vibrator stirs
• the handset receives a notification that the alarm has been received by the system. This
is a system dependent feature.
• if configured, the ALS (see
the alarm has been sent, or a call is established to a predefined number (see
Automatic Call after Alarm
• information about the handset's location is sent along with the alarm, see
with Location Information
6.1.2

Personal Alarm

Press the push-button
displayed.The following occurs;
• a beep is heard
• the orange LED flashes twice
• the vibrator stirs
• the handset receives a notification that the alarm has been received by the system. This
is a system dependent feature.
• if configured, the ALS (see
the alarm has been sent, or a call is established to a predefined number (see
Automatic Call after Alarm
• information about the handset's location is sent along with an alarm, see
Location Information
6.2

Man-Down and No-Movement Alarm

Man-down alarm: If the handset is tilted 45 degrees or more for a preset time (default 7
seconds), the Man-down alarm is triggered. The accuracy of the tilt is + or - 10 degrees.
No-movement alarm: If no movement is detected during a preset time (default 30 seconds),
the No-movement alarm is triggered.
When an alarm is triggered, the following occurs;
31 October 2013 / Ver. C
can be defined to send an alarm by a long press and by multiple
6.1.2 Personal
until a dialog window "Test Alarm" is displayed. The
6.4 Acoustic Location Signal
on page 32)
on page 32.
twice or more, the dialog window "Personal Alarm" is
6.4 Acoustic Location Signal
on page 32).
on page 32.
6.1.1 Test
Alarm), and multiple
Alarm).
on page 32) is activated after
6.3 Alarm
on page 32) is activated after
6.3 Alarm with
TD 92789EN
6.5
6.5
31

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dt413Dt423Dt433

Table of Contents