During Operation - Shindaiwa DG1000MI Owner's And Operator's Manual

Sound proof diesel engine generator
Hide thumbs Also See for DG1000MI:
Table of Contents

Advertisement

3-PHASE 400/440V
BUS PLATES
The 3-phase voltage is energized to the 3-phase output terminals.
③ ③ ③ ③
Refer to 7-2. Connecting cable
④ ④ ④ ④
Starting the engine and turning the 3-phase breaker to ON, the 3-phase current is sent to the
3-phase output terminals.

9.3 During Operation

9.3.1 Post startup check
Make sure that all meters (gauges) and displays are working properly
(refer to 5. Equipment)
Check for any unusual vibration or noise
Check for any unusual color from the exhaust. Under normal condition, the exhaust fume
has no color or light bluish color.
<Caution>
If finding out abnormality, consult with the distributor or our engineering section in order to
repair, without using the machine.
9.3.2 During operation
Make minor adjustment to voltage and speed using the Frequency Adjusting Screw and
Voltage Regulator, by monitoring frequency meter, and voltage meter
■ Vacuuming the air out of the fuelling system in event of no fuel
※ ※ ※ ※
R efer to the User's manual for Engine.
This generator is equipped with automatic vacuuming feature. Thus if the engine
stops due to running out of fuel, follow the next steps to vacuum the air out.