5.1.3 Battery Charge Monitoring Lamp (charge lamp)
When the battery is not able to be charged during operation, the battery
charge-monitoring lamp will flash.
In the event this occurs, stop the engine consult with the authorized distributor or
CHARGE
our engineering section.
<Caution>
Battery Charge Monitor cannot detect the degradation of battery life nor the battery
fluid level (refer to 8-6 Checking Battery)

5.2 Gauges

5.2.1 Hour Meter (built into the Tachometer)
HOUR METER
0 0 0 0 0 H
5.2.2 Water Temperature Gauge
5.2.3 Oil Pressure Gauge
Hour Meter keeps track of utilization time. Use this meter to schedule your
Preventative Maintenance. Note that the Hour Meter will operate, as long as
the start switch is in RUN position, regardless of whether the engine is operating
or stopped.
Water Temperature Gauge displays the temperature of engine coolant. Normal
temperature may vary depending on the environment, but it should be between
75 to 90 degree Celsius.
<Caution>
If the temperature exceeds normal value, disconnect the load, idle the
engine at 1000min
temperature range.
Oil Pressure Gauge displays the pressure of engine oil. Normal pressure may
vary depending on the environment, but it should display 0.98 – 4.9 x 100kPa
2
(1-5kgf/cm
). However, under cold weather, the pressure gauge may displays
higher reading. Continue idling until the pressure falls to normal range.
- 12 -
-1
, and wait until the reading falls to the normal