9 Operation

9.1 Initializing / preparation

Exhaust fume from the engine contains many elements harmful to human.
Do not operate this equipment in poorly ventilated area, such as inside a room or in a tunnel
Caution
Do not point the exhaust fume toward pedestrians or building.
Caution
Temperature around muffler and exhaust can get extremely high. Keep any inflammable
items (such as fuel, gas, paint, etc.) away from the equipment.
Always operate this equipment on flat surface and, at least 1 meter away from any objects
(wall, box, etc.).
Caution
Always place the equipment on a flat and stable surface, to keep the equipment from
sliding.
When starting the engine, turn off the connected equipment and set the circuit breaker to
OFF position.
Turn the circuit breaker for single-phase and 3-phase on the control panel to OFF position
① ① ① ①
Set the Throttle Lever to IDLING position.
② ② ② ②
③ ③ ③ ③
Turn the starter switch to <START> position, and start the engine. In cold environment, turn
the starter switch to <Pre-heating> position, wait until the pre-heating status lamp comes on,
and start the engine
FIXING
SCREW

FREQUENCY ADJUSTING SCREW

:Suffocation from exhaust fume
:Suffocation from exhaust fume
:Fire
:Injuries

THROTTLE LEVER

3-PHASE
BREAKER
- 32 -
VOLTAGE
REGULATOR
1-PHASE
THROTTLE LEVER
BREAKER
PREHEAT
LAMP

STARTER SWITCH